OPERATION
F-1097-2305
3-9
Micro-Meter Box Calibration
for Unlisted Seeds
NOTE
Calibration Crank Assembly used for Calibration is stored
in the toolbox.
Brillion assumes no liability pertaining to Seeding Rates
achieved with this Seeder. Rates listed are general in
nature and should be used as starting points only. Seed
varieties and blends listed represent those calibrated
through in-house test meters.
Variations in actual rates may be realized due to
differences in seed lots. For accurate rates with seeds
being used, follow the calibration instructions listed on
the Seed Chart inside the Seed Box Cover or refer to this
Manual.
The information listed in the
Seed Chart is subject to change without notice.
Calibrate Unlisted Seeds as follows:
1. Seed Shaft turns 258 revolutions per acre seeded.
2. Raise machine and lock in Transport Position.
3. Place Calibration Tray in collection position to catch
seed. Remove the 5/16-18 Wing Nuts that secure the
Calibration Tray Cover over the opening in the RH
Support Plate.
Wing Nut that secures the Calibration Tray in the
Storage position. Orient the Calibration Tray with
Handle to the top and insert it into the RH Support
opening.
4. Remove Micro-Meter Drive Pin.
5. Turn Transmission Micro-Meter Shaft Calibration Hex
258 revolutions Clockwise (CW) with provided Crank,
43 turns may be used if results are adjusted as stated
in Step 6.
6. Weigh seed for approximate planting rate in lbs/acre.
Multiply weight by 6, if only 43 turns were used.
Figure 3-15: Calibration Opening Cover
Figure 3-16: Calibration Tray Collection Position
Figure 3-17: Micro-Meter Box Calibration
7. Install Micro-Meter Drive Pin.
8. Place Calibration Tray back in storage position.
Re-install Calibration Opening Cover
over the opening in the RH Support Plate with 5/16-18
Wing Nuts.
Figure 3-18: Calibration Tray Storage Position
Calibration
Opening Cover
Wing Nut,
5/16-18
RH Support
Plate Calibration
Tray Opening
RH Seed
Box Support
Calibration Tray
Calibration Tray
Storage Opening
RH Seed
Box Support
30 Tooth
15 Tooth
15 Tooth
218254
Calibration
Crank
Large Meter
Calibration Hex
Micro-Meter
Drive Pin
Idler
Calibration
Tray
Calibration
Opening Cover
Wing Nut,
5/16-18
RH Seed
Box Support
Содержание Brilllion Till'N Seed BPSB-8
Страница 4: ......
Страница 15: ...SAFETY INFORMATION F 1097 2305 1 9 TABLE OF CONTENTS Figure 1 7 Drawbar Seeder Decals 3 15 17 3 17 17...
Страница 18: ...1 12 F 1097 2305 SAFETY INFORMATION TABLE OF CONTENTS Table provided for general use NOTES...
Страница 32: ...2 14 F 1097 2305 ASSEMBLY TABLE OF CONTENTS Table provided for general use NOTES...
Страница 72: ...4 20 F 1097 2305 MAINTENANCE TABLE OF CONTENTS Table provided for general use NOTES...