103
Elevation system failure; "PO" error.
Grade pot out of
calibration or failed.
Recalibrate pot.
(See Page 74)
Does the treamill go up when UP is pressed and
down when DOWN is pressed in this mode?
Remove the 6 pin elevation connection from the
SCR control board. Is either the yellow DOWN lamp
or the yellow UP lamp on the SCR lit?
Replace SCR.
Does the yellow UP lamp on the SCR
light when UP is pressed?
Does the yellow DOWN lamp on the motor control
board light when DOWN is pressed?
Replace elevation motor.
7.1
Replace SCR.
Replace SCR.
7.3
7.2
7.4
7.5
YES
NO
YES
YES
NO
NO
NO
NO
YES
YES
Place the treadmill in Diagnostic Mode:
1. Turn OFF the treadmill.
2. L7 & L8 Executive Trainer -Press MENU and START
simultaneously.
3. For all other L7 & L8's - Press DISPLAY (or UP ARROW -
Δ
)
and START simultaneously.
Is the red GRADE lamp on the SCR lit?
Grade pot out of
calibration or failed.
Recalibrate pot.
(See Page 74)
Содержание Cardio Trainer L8
Страница 5: ...5 ...
Страница 27: ...27 Section 3 Parts Identification L8 L9 BED EXPLODED VIEW 18 ...
Страница 28: ...28 L7 BED EXPLODED VIEW L Series Upright ...
Страница 29: ...29 L SERIES UPRIGHT EXPLODED VIEW 112 ...
Страница 30: ...30 L SERIES MOTOR PAN EXPLODED VIEW 111 ...
Страница 35: ...35 COMMERCIAL MOTOR PAN SCR MOTOR CONTROL BOARD ...
Страница 36: ...36 L SERIES 110V COMMERCIAL LOWER WIRE SCHEMATIC ...
Страница 37: ...37 L SERIES 220V COMMERCIAL LOWER WIRE SCHEMATIC ...
Страница 40: ...40 L SERIES SCR UPPER WIRE HARNESS WIRING DIAGRAM ...
Страница 42: ...42 L SERIES HOME MOTOR PAN WIRING SCHEMATIC ...
Страница 47: ...47 L SERIES HOME MOTOR PAN WIRING SCHEMATIC PWM MOTOR CONTROL BOARD W RELAY ASSEMBLY ...
Страница 48: ...48 PWM MOTOR CONTROL BOARD W RELAY ASSEMBLY ...
Страница 49: ...49 L SERIES PWM UPPER WIRE HARNESS WIRING DIAGRAM ...
Страница 50: ...50 EXECUTIVE TRAINER LCD WIRING SCHEMATIC ...
Страница 110: ...110 L SERIES ROAD RUNNER LOWER WIRING DIAGRAM ...
Страница 111: ...111 L SERIES ROAD RUNNER UPPER WIRING SCHEMATIC ...