SPECIFICATIONS & FEATURES

DIMENSIONS

 

Width

: 30.0 inches (762 mm)

 

Depth

: 34.25 inches (869.95 mm)

 

Height

: 40.6 inches (1031.24 mm)

WEIGHT

 Shipping

: 290 lbs (132 kg) 

 

Operating (w/ Ice)

: 570 lbs (259 kg)

 

Ice Capacity

: 280 lbs (127 kg)

CARBON DIOXIDE (CO

2

) SUPPLY

 

Min Pressure

: 70 psi (0.483 MPa)

 

Max Pressure

: 80 psi (0.552 MPa)

FITTINGS

 

Carbonator Inlet

: 3/8 inch barb

 

Plain Water Inlet

: 3/8 inch barb

 

Brand Syrup Inlets

: 3/8 inch barb

 

Ambient Flavor Inlets: 3/8 inch barb

 

CO

2

 Inlet

: 3/8 inch barb

ELECTRICAL

 

115 VAC / 60 Hz / 5.0 Amps

CARBONATED WATER SUPPLY

 

Min Flowing Pressure

: 25 psi (0.172 MPa)

 

Max Static Pressure

: 50 psi (0.345 MPa)

PLAIN WATER SUPPLY

 

Min Flowing Pressure

: 75 psi (0.517 MPa)

This unit emits a sound pressure level below 70 dB

 

Your Service Agent:

 

Service Agent Telephone Number: 

 

Serial Number:

 

Model Number:

This manual was developed by the Lancer Worldwide as a reference for the owner/operator and installer of this  

dispenser. Please read this guide before installation and operation of this dispenser. If service is required please call your 

Lancer Service Agent or Lancer Customer Service. Always have your model and serial number available when you call. 

READ THIS MANUAL

Provide an adequate potable water supply. Water pipe connections and fixtures directly connected to a potable water supply must 

be sized, installed, and maintained according to federal, state, and local laws. The water supply line must be at least a 3/8 inches 

(9.525 mm) pipe with a minimum of 25 psi (0.172 MPa) line pressure, but not exceeding a maximum of 50 psi (0.345 MPa).  

Water pressure exceeding 50 psi (0.345 MPa) must be reduced to 50 psi (0.345 MPa). Use a filter in the water line to avoid equip

-

ment damage and beverage off-taste. Check the water filter periodically, as required by local conditions. The water supply must 

be protected by means of an air gap, a backflow prevention device or another approved method to comply with NSF standards. A 

leaking inlet water check valve will allow carbonated water to flow back through the pump when it is shut off and contaminate the 

water supply. Ensure the backflow prevention device complies with ASSE and local standards. It is the responsibility of the installer 

to ensure compliance.

Water Notice

Assurez-vous que l’alimentation en eau potable est suffisante. Les branchements et les raccords de tuyauterie d’eau directement reliés à 

l’alimentation en eau potable doivent avoir la taille appropriée et être installés et entretenus conformément aux codes provincial et local. 

La conduite d’alimentation en eau doit avoir un diamètre minimum de 3/8 po (9,525 mm) et une pression minimale de 25 psi (0,

172 Mpa) 

sans toutefois excéder 50 psi (0,345

 Mpa). Si la pression d’eau excède 50 psi (0,345 Mpa), réglez le régulateur de pression à 50 psi 

(0,345 Mpa). Inspectez le filtre à eau régulièrement, selon les conditions du réseau local. Le circuit d’alimentation en eau doit être protégé 

au moyen d’un clapet antiretour, ou d’un dispositif antirefoulement ou d’une autre méthode conforme aux normes de la NSF. Dans le cas 

d’une fuite du clapet antiretour de la conduite d’alimentation, l’eau gazéifiée refoule à travers la pompe (lorsqu’elle n’est pas en service) et 

contamine ainsi l’alimentation en eau. Assurez-vous que le dispositif antirefoulement est conforme aux normes de l’ASSE et aux codes en 

vigueur localement. Cette tâche est de la responsabilité de l’installateur.

Remarque relative à l’eau

VEUILLEZ LIRE CE MANUEL

Ce manuel élaboré par Lancer Worldwide est un outil de référence à l’intention des propriétaires, utilisateurs et installateurs de 

cette distributrice. Veuillez lire ce manuel avant d’installer et d’utiliser cet appareil. Pour l’entretien, communiquez avec le service 

à la clientèle de Lancer ou avec un technicien autorisé. Ayez sous la main le numéro de série et le modèle de distributrice lors de 

votre appel. 

Содержание Twin Pour 30

Страница 1: ...not be used by children or infirm persons without supervision This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or la...

Страница 2: ...hez pas cet appareil dans une prise lectrique multiple partag e par d autres appareils Ne placez pas plusieurs prises d alimentation multiples portables ou alimentations lectriques portables l arri re...

Страница 3: ...an air gap a backflow prevention device or another approved method to comply with NSF standards A leaking inlet water check valve will allow carbonated water to flow back through the pump when it is s...

Страница 4: ...aining three sides Level unit if necessary For optimum perfor mance place the unit at a 0 tilt The maximum tilt is 5 Leveling the Dispenser NSF listed units must be sealed to the counter NOTE To ensur...

Страница 5: ...at se trouve dans le bac gla ons Durant le cycle d agitation automatique et lors de la distribution des gla ons veiller ce que l espace soit suffisant entre le dessus de l amas de gla ons et le bas de...

Страница 6: ...nect tubing to all syrup inlets See Plumbing Diagrams on page 26 for reference NOTE 12 Route drain hose from designated open type drain to fitting on Drip Tray and connect hose to fitting if applicabl...

Страница 7: ...E 13 Attach fan bracket to fan assembly using screws provided Condensation Fan Installation 14 Install condensation fan on the underside of the unit by 1 pushing fan bracket into slots in the right wa...

Страница 8: ...OT TURN ON CO2 SUPPLY AT THIS TIME WARNING 7 Repeat Step 6 for both low pressure CO2 regulators on the regulator manifold routed to the unit and the syrup pumps 5 Connect tubing routed from the tee at...

Страница 9: ...the service menu for drink setup must be accessed 10 Access the Service Menu by turning the keyswitch clock wise to the third position 6 Turn on the power to the dispenser by pressing the on off toggl...

Страница 10: ...oth of the low pressure regulators on the regulator manifold to 75 psi 0 517 MPa then tighten locknut with wrench 22 Activate each soda module until gas out 23 Plug in the remote carbonator pump deck...

Страница 11: ...button on the lower left corner to return to the Valve Configuration Screen 7 Repeat Steps 3 and 5 for any of the other brand or flavor modules 8 Tap the Back button to return to the Service menu 12 T...

Страница 12: ...bration button 2 Tap the Calibrate on the Water Valve to be calibrated Calibrating Plain Carbonated Water Modules Fill to 200 ml Graduated Cylinder CALIBRATION MAINTENANCE 4 Set the Timer to the ON po...

Страница 13: ...r reference The water flow rate was set to 73 93 ml sec which makes the final syrup flow rate 14 79 ml s The finished drink flow rate dispensed will be 88 72 ml s NOTE A B C D Increase Decrease A Flow...

Страница 14: ...ttach outer nozzle by pushing up and twisting clockwise until snug 5 Enter the brand calibration screen from the previous section steps 1 2 6 Set the Timer to the ON position and select Time as the Op...

Страница 15: ...The following is a set of instructions on how to set up this feature If no sold out sensor is assigned then the Auto feature acts the same as the Ready feature NOTE Sold Out Features 1 From the Servic...

Страница 16: ...d scroll down and press Accept to confirm and save changes It may take up to 10 minutes for a network connection to be established NOTE 2 From the service menu select Network Status to change connecti...

Страница 17: ...into open port on the side of the PCB controller box 4 Access the Service menu on the left side screen and tap the Data Management button Update Brands Flavors 1 Create a USB drive with the updated b...

Страница 18: ...ment aux lignes directrices de la NSF L exploitant de l quipement doit en assurer l entretien continu comme indiqu dans ce manuel ou selon les lignes directrices du minist re de la Sant afin d assure...

Страница 19: ...n Box on page 21 Pull out unit if applicable and clean behind and underneath Check for any loose components or noises Other Supplies Needed 1 Clean cloth towels 2 Bucket 3 Extra nozzle 4 Sanitary glov...

Страница 20: ...in the sanitizing solution using the nozzle brush dip the brush in the nozzle sanitizing solution and thoroughly brush the bottom of the inner nozzle body 6 Rinse the brush in warm 90 110 F 32 2 43 3...

Страница 21: ...all sides of the Ice Bin and surface of the aluminum casting 5 Place syrup lines with BIB connectors and any adapters into cleaning solution 6 Activate each valve until lines are filled with cleaning...

Страница 22: ...coming CO2 pressure is between 70 psi 0 483 MPa and 80 psi 0 552 MPa 2 Open shutoff fully 3 Remove soda flow control from valve and clean out any foreign material to ensure smooth spool movement Insuf...

Страница 23: ...to syrup pump too low 5 Stalled or inoperative BIB pump 6 Kinked line 7 CO2 regulator malfunction 1 Replace syrup BIB as required 2 Open shutoff completely 3 Remove valve from mounting block open shu...

Страница 24: ...Wiring harness not plugged in 3 PC board defective 4 Malfunctioning power supply 1 Connect dispenser to power source 2 Plug in wiring harness 3 Replace PC board 4 Check voltage to power supply Check f...

Страница 25: ...ck BIB connector if still leaking then re place line 2 Replace o ring 3 Replace defective pump BIB pump fails to restart after bag replacement 1 BIB connector not on tightly 2 BIB connector is stopped...

Страница 26: ...12 14 16 2 4 6 16 8 10 12 14 1 3 5 7 9 NC 11 13 15 NC 1 3 5 15 7 9 11 13 BLK WHT GRY BLK PUR BLU GRN YEL ORG RED BRN VIO BLK BLK GRN BLK BRN BLK ORG BLK BLK BLK GRY PUR BLU GRN YEL ORG RED BRN WHT BLK...

Страница 27: ...R USB DC BLOCK OK POWER CORD CONDENSATION FAN PRIMARY PCB SECONDARY PCB POUR BUTTON POUR BUTTON GPIO ICE DOOR TRIGGER VALVEHARN RIGHT VALVEHARN LEFT SBC USB A TO USB B DIO PCB POWER SUPPLY USB A MALE...

Страница 28: ...SATION FAN PRIMARY PCB SECONDARY PCB GRN DC FAN AC OUT AC VOLT TO SUPPLY GRN BLU BLK DIO PCB BLK RED RED BLK BLK RED DENOTES DEFAULT 3 2 SW2 SWITCH 2 POSITION DOES NOT MATTER 4 ON LANCER PN 06 3289 01...

Страница 29: ...29...

Страница 30: ...A HOSHIZAKI COMPANY 6655 Lancer Boulevard San Antonio TX 78219 lancerworldwide com...

Отзывы: