6
4. If necessary, install water booster (Lancer PN MC-163172)
between water supply and the remote pump deck.
5.
Using tubing cutters, cut the water line and install U-fitting
then route appropriate tubing from the U-fitting to the plain
water inlet at the unit.
A
B
C
A. Line to Water Source
B. U-Fitting
C. Line to Remote Pump Deck
D. Line to Plain Water Inlet
D
A
A. Remote Pump Deck
B. Pump Inlet
C. Pump Outlet
D. Line to Carb Inlet
B
C
D
7. Route appropriate tubing from the remote pump deck outlet
to the carbonated water inlet at unit.
A
B
A. Oetiker Pliers
B. Tubing
C. Syrup/Water
Inlet
C
8. Install a shut-off valve in the water line feeding the remote
pump deck as well as the water line feeding the plain water
inlet.
6. Route appropriate tubing from the syrup pump location to the
syrup inlets and connect tubing to all syrup inlets.
See Plumbing Diagrams on page 26 for reference.
NOTE
12.
Route drain hose from designated open type drain to fitting
on Drip Tray and connect hose to fitting. (if applicable)
A
A. Drain Fitting
B. Drain Line
C. Drip Tray
B
C
DO NOT PLUG UNIT INTO GROUNDED ELECTRICAL
OUTLET AT THIS TIME.
Make sure that all water lines
are tight and unit is dry before making any electrical
connections
F
WARNING
10. Route appropriate tubing from the CO
2
source location to the
CO
2
inlet on the unit and connect tubing to inlet.
11. Route the power supply cord to a grounded electrical outlet
of the proper voltage and amperage rating.
9. Insert and install carbonator probe.
À CE STADE, NE PAS BRANCHER L’UNITÉ DANS UNE
PRISE SECTEUR DE TERRE.
Veiller à ce que l’ensemble
des canalisations d’eau soient fixées solidement et que
l’unité soit bien sèche avant d’effectuer des branchements
électriques.
!
MISE EN GARDE
Voir les schémas de plomberie à l’avant de l’unité ou à
la page 26 pour référence.
REMARQUE
Содержание Twin Pour 30
Страница 29: ...29...
Страница 30: ...A HOSHIZAKI COMPANY 6655 Lancer Boulevard San Antonio TX 78219 lancerworldwide com...