8
Installing CO
2
Supply
1. Connect high pressure CO
2
regulator assembly to CO
2
cylinder or bulk system.
-
Thread regulator nut on to tank, then
tighten nut with wrench
A. CO
2
Regulator
B. Outlet
C. Wrench
D. CO
2
Supply
A
B
C
D
Before installing regulator, ensure that a seal (washer
or o-ring) is present in regulator attachment nut.
!
ATTENTION
2.
Connect a 1/4” nut, 3/8” stem and seal to CO
2
regulator
outlet.
A dedicated CO
2
regulator is required to supply the CO
2
inlet at the unit as well as to all syrup pumps.
!
ATTENTION
A
B
C
D
A. Line to Dispenser
B. Line to Syrup Pumps
C. Line to CO
2
Regulator
D. CO
2
Regulator Manifold
6. Using a wrench, loosen lock nut on the regulator adjustment
screw of the high pressure CO
2
regulator connected to the
source, then using a screwdriver back out lock nut screw all
the way.
DO NOT TURN ON CO
2
SUPPLY AT THIS TIME
!
WARNING
7. Repeat Step 6 for both low pressure CO
2
regulators on the
regulator manifold routed to the unit and the syrup pumps.
5. Connect tubing routed from the tee at the syrup pumps to the
second low pressure regulator.
A. CO
2
Regulator
B. Screwdriver
C. Regulator Adjustment Screw
A
B
C
A. CO
2
Regulator
B. Wrench
C. 1/4” nut, Stem
D. CO
2
Supply
A
B
C
D
3. Route appropriate tubing from the low pressure CO
2
regulator manifold location to the 1/4” nut, 3/8” stem on the
high pressure CO
2
regulator attached to source and connect
tubing.
4. Connect tubing routed from the CO
2
inlet at the unit to one of
the low pressure CO
2
regulator manifold outlets.
Avant d’installer le détendeur, veiller à ce que l’écrou de
montage du détendeur soit muni d’un joint d’étanchéité
(rondelle ou joint torique).
!
ATTENTION
NE PAS OUVRIR L’ALIMENTATION EN CO
2
À CE STADE.
!
MISE EN GARDE
Un régulateur de CO2 dédié est nécessaire pour alimenter
l’entrée de CO2 à l’unité ainsi qu’à toutes les pompes à
sirop.
!