IBD 4500/4600/LCD
16
CONTINUED ON NEXT PAGE
3. CLEANINg AND SANITIZINg INSTRUCTIONS
gENERAL INFORMATION
A. The cleaning and sanitizing procedures provided herein pertain to the Lancer equipment
identified by this manual. If other equipment is being cleaned, follow the guidelines established
by the manufacturer for that equipment.
B. Lancer equipment (new or reconditioned) is shipped from the factory cleaned and sanitized
in accordance with NSF guidelines. The equipment must be cleaned and sanitized after
installation is complete. The operator of the equipment must provide continuous maintenance
as required by this manual and state and local health department guidelines to ensure
proper operation and sanitation requirements are maintained.
C. Cleaning and sanitizing should be accomplished only by trained personnel. Sanitary gloves are
to be used during cleaning and sanitizing operations. Applicable safety precautions must be
observed. Instruction warnings on the product being used must be followed.
D. Other Required Supplies: 1) Clean cloth towels, 2) bucket, 3) extra nozzle, 4) sanitary gloves and
5) Small brush (PN 22-0017 included with installation kit).
DO NOT USE A WATER JET TO CLEAN OR SANITIZE THE UNIT
DO NOT DISCONNECT WATER LINES WHEN CLEANINg AND SANITIZINg SYRUp LINES,
TO AvOID CONTAMINATION.
DO NOT USE STRONg BLEACHES OR DETERgENTS; THESE CAN DISCOLOR AND
CORRODE vARIOUS MATERIALS.
DO NOT USE METAL SCRApERS, SHARp OBJECTS, STEEL WOOL, SCOURINg pADS,
ABRASIvES, OR SOLvENTS ON THE DISpENSER.
DO NOT USE HOT WATER ABOvE 140º F (60º C). THIS CAN DAMAgE THE DISpENSER.
DO NOT SpILL SANITIZINg SOLUTION ON ANY CIRCUIT BOARDS. INSURE ALL SANITIZ-
INg SOLUTION IS REMOvED FROM THE SYSTEM.
USE SANITARY gLOvES.
OBSERvE AppLICABLE SAFETY pRECAUTIONS.
3.2 SANITIZINg SOLUTION
Prepare sanitizing solutions in accordance with the manufacturer’s written recommendations and
safety guidelines. The solution must provide 50 to 100 parts per million (PPM) chlorine (e.g. Sodium
Hypochlorite or bleach). A minimum of five gallons of sanitizing solution should be prepared. Any
sanitizing solution may be used as long as it is prepared in accordance with the manufacturer’s written
recommendations and safety guidelines, and provides 50 to 100 parts per million (PPM) chlorine.
3.1 CLEANINg SOLUTION
Mix a mild, non-abrasive detergent (e.g. Sodium Laureth Sulfate, dish soap) with clean, potable water
at a temperature of 90 to 110°F (32 to 43°C). The mixture ratio is one ounce of cleaner to two gallons
of water. Prepare a minimum of five gallons of cleaning solution. Do not use abrasive cleaners or
solvents because they can cause permanent damage to the unit. Ensure rinsing is thorough, using
clean, potable water at a temperature of 90 to 110 degrees F. Extended lengths of product lines may
require additional cleaning solution.
Содержание 4400 Series
Страница 30: ...7 2 FINAL ASSEMBLY pOST MIX IBD AND ICE DISpENSER 30 IBD 4500 4600 LCD...
Страница 32: ...IBD 4500 4600 LCD 32 7 3 LCD UNIT FINAL ASSEMBLY pOST MIX IBD AND ICE DISpENSER...
Страница 34: ...IBD 4500 4600 LCD 34 7 4 4600 NO COLD pLATE UNIT FINAL ASSEMBLY pOST MIX IBD AND ICE DISpENSER...
Страница 41: ...7 8 WIRINg DIAgRAM 115v 60HZ 41 OPERATIONS AND SERVICE MANUAL PN 28 0255 11...
Страница 42: ...IBD 4500 4600 LCD 42 7 9 WIRINg DIAgRAM 230v 50 60HZ...
Страница 45: ...OPERATIONS AND SERVICE MANUAL PN 28 0255 11 7 13 IBD 22 COUNTER CUTOUT 45...
Страница 46: ...7 14 IBD 30 COUNTER CUTOUT 46 IBD 4500 4600 LCD...