IBD DISPENSER WITH ICEMAKER
Install
the icemaker per manufacturer specifications.
Points of consideration include drainage, ventilation,
and drop zones.
An adapter plate
is required when installing an ice-
maker. Contact your Sales Representative or Lancer
Customer Service for more information.
A bin thermostat
is required in order to control the
level of ice in the dispenser. Contact your icemaker
manufacturer to obtain the correct bin thermostat.
Ensure
the icemaker is installed properly to allow for
removal of the merchandiser.
Ensure
manual fill is accessible.
Clean and maintain
icemaker per manufacturer’s
instructions.
FIgURE 4
IBD 4500/4600/LCD
12
1.4 LEvELINg THE DISpENSER
In order to facilitate proper dispenser drainage and carbonation,
ensure that the dispenser is level, front to back and side to side.
Place a level on the top of the rear edge of the dispenser. The
bubble must settle between the level lines (Fig 5
).
Repeat this
procedure for the remaining three sides. Level unit if necessary.
For optimum performance place the unit at a 0 degree tilt. The
maximum tilt is 5 degrees.
1.5 CONNECTINg TO WATER SUppLY LINES
NOTE: In addition to the following WATER NOTICE, adhere to the WATER SUppLY
Warnings and Cautions, page 6.
FIgURE 5
WATER NOTICE
For the plain water supply line, the inlet water flowing pressure should be at least 75 PSI (517.11
kPa). If the water pressure is lower than 75 PSI (517.11 kPa) flowing, use a water booster system.
If the water flowing pressure is lower than 75 PSI (517.11 kPa) at the plain water inlet and a water
booster is NOT installed, water products will not hold a proper flow rate or water/syrup ratio. Flow
conditions at the nozzle can also be affected, causing poor nozzle coning and mixing.
For the soda water supply line, do not exceed 50 PSI (137.9 kPa) for the inlet water static pressure
going into the carbonator pump. If the static water pressure exceeds 50 PSI (137.9 kPa), install a
water regulator before the carbonator water inlet.
The Lancer Water Booster/Tank (PN MC-163172) is offered as a kit. The water booster must be
installed as close as possible to the plain water circuit inlet.
Install the water regulator (Lancer PN 18-0306) included with unit as close as possible to the water
carbonator pump inlet. The recommended water pressure value feeding the carbonator is a minimum
of 25 PSI 172.37 kPa). If the normal water pressure does not exceed 50 PSI (137.9 kPa), but fluctu-
ates over this value (for example, when water usage on other equipment connected to the same
water supply causes pressure spikes), use a water regulator.
Содержание 4400 Series
Страница 30: ...7 2 FINAL ASSEMBLY pOST MIX IBD AND ICE DISpENSER 30 IBD 4500 4600 LCD...
Страница 32: ...IBD 4500 4600 LCD 32 7 3 LCD UNIT FINAL ASSEMBLY pOST MIX IBD AND ICE DISpENSER...
Страница 34: ...IBD 4500 4600 LCD 34 7 4 4600 NO COLD pLATE UNIT FINAL ASSEMBLY pOST MIX IBD AND ICE DISpENSER...
Страница 41: ...7 8 WIRINg DIAgRAM 115v 60HZ 41 OPERATIONS AND SERVICE MANUAL PN 28 0255 11...
Страница 42: ...IBD 4500 4600 LCD 42 7 9 WIRINg DIAgRAM 230v 50 60HZ...
Страница 45: ...OPERATIONS AND SERVICE MANUAL PN 28 0255 11 7 13 IBD 22 COUNTER CUTOUT 45...
Страница 46: ...7 14 IBD 30 COUNTER CUTOUT 46 IBD 4500 4600 LCD...