background image

PAGE 18

DRIVE ASSEMBLY 

(refer to pages 12 & 13 for diagrams)

:

Remove the valve cover to access the drive assembly.

Disconnect the power source plug (black wire) from the PC board prior to disconnecting the motor or water meter plugs 

from the PC board. The power source plug connects to the four-pin jack. The motor plug connects to the two-pin jack on 

the left-hand side of the PC board. The water meter plug (gray wire) connects to the three-pin jack on the far right-hand 

side of the PC board.

The PC board can be removed separately from the drive bracket but it is not recommended. Do not attempt to remove the 

display panel from the PC board. Handle the board by the edges. To remove the PC board from the drive bracket, unplug 

the power, water meter and motor plugs from the PC board. Lift the middle latch along the top of the drive bracket while 

pulling outward on the top of the PC board. The drive bracket has two plastic pins that fit into the holes on the lower edge 

of the PC board. Once the PC board is tilted about 45° from the drive bracket it can be lifted off of these pins. To reinstall 

the PC board, position the lower edge of the PC board so that the holes in the PC board line up with the plastic pins. Push 

the top of the PC board towards the valve until it snaps under the middle latch, weave the power and water meter wires 

into the holders and reconnect the motor, water meter and power plugs.

The drive bracket must be removed to access the drive cap assembly and pistons or the drive gear cover. It is not 

necessary to remove the PC board from the drive bracket to remove the drive bracket. To remove the drive bracket start 

by removing the plugs for the power source and the water meter. Unweave the wires from the side holders. Two tabs on 

the top of the drive back plate hold the drive bracket in place. Simultaneously lift the two tabs and gently ease the top of 

the drive bracket forward. The lower edge of the drive bracket has two notches that rest on the drive back plate. Lift up 

and outward on the drive bracket to disengage the notches.
To reassemble, seat the bottom of the drive bracket so the notches are engaged at the bottom of the drive back plate. 

Push the top of the drive bracket toward the two latches. The drive bracket may have to be lifted slightly to let the 

threaded piston rod pass through the hole in the drive bracket. Maintain a slight engaging force on top of the drive bracket 

while deflecting the bracket slightly to the left by pressing on the side of the upper right corner. This helps the drive gears 

mesh with the drive cap assembly. The drive bracket is properly seated when it snaps under the latches on the drive back 

plate. If resistance is felt before latching, then notches are not fully engaged, the piston rod is not in hole, the wires are 

jammed between the drive bracket and drive back plate, or the gear is not engaging the drive cap assembly. 

To inspect the drive gears, the drive gear cover needs to be removed. Before trying to remove the gear cover, the drive 

bracket must be removed from the drive back plate. (Refer to the instructions above regarding removing the drive bracket 

from the drive back plate. The drive gear cover can be removed from the drive bracket without removing the motor or the 

PC board.) The drive gear cover is held in place on the drive bracket by three clips. The largest of the three clips is always 

orientated to the bottom of the drive bracket. With the PC board facing up, push in and down on the large clip on the drive 

gear cover. Handle the cover and the gears carefully so that the gears do not fall off the pegs in the cover.

Replace broken or damaged drive gears. Do not lubricate any of the gears. Avoid getting any foreign matter on the 

reflective coating because dirt or oils may interfere with pulse counting. 
The drive gear cover only fits on one way, with the large clip orientated towards the bottom. If all three clips are outside of 

the gear shroud on the drive bracket the drive gear cover slips easily into place. 
The drive bracket does not need to be removed from the drive plate if the motor needs to be removed. To remove the 

motor, disconnect the power and motor plugs from the jacks on the PC board. Move the spring clip loop to the right and 

hold. Rotate the motor at least a ¼ turn in either direction so the wires are vertical (up & down) before gently pulling on the 

wire connectors to remove the motor. Pulling directly on the wires without rotating the motor may break the wires off the 

motor. 
Replace the motor if necessary. Do not lubricate the motor or the gears. To reinstall the motor, move the spring clip loop 

to the right and hold. Gently turn the motor while inserting so that the gear on the motor meshes with the gears under 

the drive gear cover. Release the spring clip loop and continue to rotate the motor until the wires are horizontal and the 

motor housing engages the small plastic bulge inside the drive bracket motor retainer. Reconnect the motor plug to the 

two-pronged jack on the lower left side of the PC board. If the motor will not easily engage with the drive gears when 

reinstalling, lift and slightly rotate the motor before reinserting. Reconnect the power plug.
Replace the valve cover. After completing any valve maintenance involving the drive assembly or the drive cap assembly 

and pistons, unplug power source jack from the printed circuit board (black wire) and plug back in or

 

press and hold 

NEXT

 and 

REGEN

 buttons for 3 seconds.

This resets the electronics and establishes the service piston position. The display should flash the software version and 

then reset the valve to the service position.

SERVICE INSTRUCTIONS

Содержание City Soft Plus XFactor Series

Страница 1: ...free service When installed in accordance with the following instructions and if given reasonable care clear soft water will be the result For servicing and future inspection purposes please file this...

Страница 2: ...Total Gallons Per Day x Grains Per Gallon of hardness Total Grains per Day INSTALLATION DATE SERIAL NUMBER INSTALLER NAME PHONE ADDRESS TABLE OF CONTENTS Job Specifications 2 Pre Installation Review...

Страница 3: ...r treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after treatment GENERAL INSTALLATION AND SERVICE WARNINGS PRE INSTALLATION REVIEW WATER...

Страница 4: ...rs are glass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o...

Страница 5: ...pes that are connected on the drain line control fitting Failure to do this could cause interior damage to the drain line flow control fitting Never insert a drain line into a drain sewer line or trap...

Страница 6: ...WITH BRINE TANK OVERFLOW GRAVITY DRAIN ONLY USED IN CASE OF MALFUNCTION IN THE BRINE SHUTOFF DO NOT CONNECT TO CONTROL VALVE DRAIN LINE IF UNIT IS INSTALLED WHERE OVERFLOW COULD CAUSE WATER DAMAGE CO...

Страница 7: ...least 1 2 full is recommended SANITIZING Use 2 oz of 5 unscented household chlorine bleach for each cubic foot of resin Pour bleach directly into the 4 diameter white brine well located inside the br...

Страница 8: ...Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the or buttons The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon...

Страница 9: ...rn to previous digit Banner Text Set the banner text up to a maximum of 44 characters Use the or to select letters of the alphabet numbers ampersand or a space in the banner text Press NEXT to forward...

Страница 10: ...Adaptor Input Voltage Hertz 120V AC 60 Hz AC Adaptor Output Voltage Current 12V AC 500 mA 3 Volt Lithium Coin Cell Battery type 2032 PC Board Relay Terminal Block DC Output Voltage 12V DC Relay Speci...

Страница 11: ...SDCS 1 A8056 Centaur Carbon for chloramine reduction in 7 LESDCS 1 6 A4074 3 4 Cu Ft 39 LBS Ion Exchange Resin for Model 7 LXD 75 1 A4074 1 Cu Ft 52 LBS Ion Exchange Resin for Model 7 LXD 100 1 A4074...

Страница 12: ...sh down to fully seat Battery replacement is 3 volt lithium coin cell type 2032 Correct Battery Orientation 1 2 3 5 6 4 X FACTOR FRONT COVER AND DRIVE ASSEMBLY After completing any valve maintenance i...

Страница 13: ...etailed service instructions 1 2 3 4 5 INJECTOR CAP INJECTOR SCREEN INJECTOR PLUG AND O RING Drawing No Order No Description Qty 1 V3005 Spacer Stack Assembly 1 2 V3004 Drive Cap Assy 1 3 V3178LP Back...

Страница 14: ...RITICAL OR HEALTH EFFECT APPLICATIONS The nut and caps are designed to be unscrewed or tightened by hand or with the service spanner wrench see page 16 If necessary a pliers can be used to unscrew the...

Страница 15: ...wing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3191 Vertical Adapter 2 INSTALLATION FITTING ASSEMBLIES 4 Water Flow Proper DLFC orient...

Страница 16: ...2 8 V3152 O ring 135 2 9 V3155 O ring 112 2 10 V3156 O ring 214 2 BYPASS VALVE Order No V3193 Although no tools are necessary to assemble or disassemble the valve the wrench shown in various position...

Страница 17: ...antity of 24 Order No V3007 09 Description Fitting 1 1 Brass Sweat Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3375 Fit...

Страница 18: ...are not fully engaged the piston rod is not in hole the wires are jammed between the drive bracket and drive back plate or the gear is not engaging the drive cap assembly To inspect the drive gears t...

Страница 19: ...embly and hand tighten the drive cap assembly Continue to tighten the drive cap assembly using a screwdriver as a ratchet until the black o ring on the spacer stack assembly is no longer visible throu...

Страница 20: ...used Sharp objects which can score the plastic should not be used to clean the injector Scoring the injector or increasing the diameter of the hole could change the operating parameters of the inject...

Страница 21: ...eter f Defective PC Board f Replace PC Board 4 Control valve regenerates at wrong time of day a Power outage a Reset time of day If PC Board has battery back up present the battery may be depleted See...

Страница 22: ...possible increase pump switch cut in to 25 psi b Incorrect injector size b Replace injector with correct size for the application c Restricted drain line c Check drain line for restrictions or debris...

Страница 23: ...NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect c Main drive gear too tight c Loosen main...

Страница 24: ...reconnect c MAV NHBP motor not fully engaged with reduction gears c Properly insert motor into casing do not force into casing Press NEXT and REGEN buttons for 3 seconds to resynchronize software wit...

Страница 25: ...PAGE 25 NOTES...

Страница 26: ...PAGE 26 A DIVISION OF C B TOOL CO 1340 MANHEIM PIKE LANCASTER PA 17601 3196 TEL 717 397 3521 FAX 717 392 0266 www lancasterwatertreatment com E mail info lancasterpump com 4 14...

Отзывы: