![Lancaster City Soft Plus XFactor Series Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/lancaster/city-soft-plus-xfactor-series/city-soft-plus-xfactor-series_installation-operating-and-service-manual_3539350006.webp)
PAGE 6
BRINE LINE FITTING CONNECTIONS
DRAIN LINE FITTING CONNECTION USING 5/8" POLY TUBE
Click to buy NOW!
PD
F-XCHANGE
w
ww
.docu-track.c
om
Click to buy NOW!
PD
F-XCHANGE
w
ww
.docu-track.c
om
WATER CONDITIONER
BYPASS PLUMBING
RECOMMENDED
IF
OPTIONAL BP2000
BYPASS VALVE
IS NOT USED.
TO
DRAIN
TO
OUTSIDE
TAP
BRINE TANK
WATER
HEATER
DRAIN LINE
AIR GAP
ADAPTER
FROM
WATER MAIN
COLD
HOT
MINIMUM 10 FEET
BETWEEN
WATER CONDITIONER OUTLET
AND
WATER HEATER INLET
LOCATE WATER CONDITIONER
AS CLOSE AS POSSIBLE
TO BRINE TANK.
A SIX FOOT LENGTH OF 3/8" O.D.
BRINE LINE POLYTUBE
SUPPLIED WITH BRINE TANK.
OVERFLOW GRAVITY DRAIN - ONLY USED IN CASE OF MALFUNCTION IN THE BRINE SHUTOFF. DO NOT CONNECT TO CONTROL VALVE DRAIN LINE.
IF UNIT IS INSTALLED WHERE OVERFLOW COULD CAUSE WATER DAMAGE, CONNECT TUBING AND RUN TO FLOOR DRAIN. DO NOT RUN TUBING ABOVE OVERFLOW HEIGHT.
CITY WATER
INSTALLATION
WATER
METER
LOCATE WATER CONDITIONER CLOSE TO A DRAIN.
AVOID OVERHEAD DRAIN LINES IF POSSIBLE TO
PREVENT BACK PRESSURE ON BRINE INJECTOR.
IF OVERHEAD DRAIN LINE IS USED AND EXCEEDS
5 FEET ABOVE CONNECTION ON CONTROL VALVE
OR
IF DRAIN LINE EXCEEDS 20 FEET IN LENGTH,
DRAIN LINE PIPE SIZE SHOULD BE MINIMUM 3/4".
Click to buy NOW!
PD
F-XCHANGE
w
ww
.docu-track.c
om
Click to buy NOW!
PD
F-XCHANGE
w
ww
.docu-track.c
om
Содержание City Soft Plus XFactor Series
Страница 25: ...PAGE 25 NOTES...