background image

PAGE 19

DRIVE CAP ASSEMBLY, MAIN PISTON AND REGENERANT PISTON

 (refer to pages 12 &13 for diagrams)

:

The drive assembly must be removed to access the drive cap assembly. The drive cap assembly must be removed to 

access the piston(s). The drive cap assembly is threaded into the control valve body and seals with an o-ring. To remove 

the drive cap assembly use the special plastic service spanner wrench (see page 16) or insert a ¼” to ½” flat blade 

screwdriver into one of the slots around the top 2” of the drive cap assembly so it engages the notches molded into the 

drive back plate around the top 2” of the piston cavity. See figure below. The notches are visible through the holes. Lever 

the screwdriver so the drive cap assembly turns counter clockwise. Once loosened unscrew the drive cap assembly by 

hand and pull straight out.

The drive cap assembly contains the drive cap, the main drive gear, drive cap spline, piston rod and various other parts 

that should not be dissembled in the field. The only replaceable part on the drive cap assembly is the o-ring. Attached to 

the drive cap assembly is the main piston and a regenerant piston.
The regenerant piston (the small diameter one behind the main piston) is removed from the main piston by pressing 

sideways and unsnapping it from its latch. Chemically clean in dilute sodium bisulfite or vinegar, or replace the regenerant 

piston if needed. To remove the main piston fully extend the piston rod and then unsnap the main piston from its latch by 

pressing on the side with the number. Chemically clean in dilute sodium bisulfite or vinegar, or replace the main piston.

Reattach the main piston to the drive cap assembly. Reattach the regenerant piston (if needed) to the main piston. 

Reinsert the drive cap assembly and piston into the spacer stack assembly and hand tighten the drive cap assembly. 

Continue to tighten the drive cap assembly using a screwdriver as a ratchet until the black o-ring on the spacer stack 

assembly is no longer visible through the drain port. Excessive force can break the notches molded into the drive back 

plate. Make certain that the main drive gear still turns freely. The exact position of the piston is not important as long as 

the main drive gear turns freely.
Reattach the drive assembly to the control valve and connect all plugs. After completing any valve maintenance involving 

the drive assembly or the drive cap assembly and pistons, unplug power source jack from the printed circuit board (black 
wire) and plug back in or press and hold 

NEXT

 and 

REGEN

 buttons for 3 seconds.

This resets the electronics and establishes the service piston position. The display should flash the software version and 

then reset the valve to the service position.

REFILL FLOW CONTROL ASSEMBLY

 (refer to page 14 for diagrams)

:

To clean or replace the refill flow control, pull out the elbow-locking clip and then pull straight up on the elbow. Replace the 

elbow locking clip in the slot so that it is not misplaced. Twist to remove the white flow control retainer. The flow control 

can be removed by prying upward through the side slots of the retainer with a small flat blade screwdriver. 
Chemically clean the flow control or the white flow control retainer using dilute sodium bisulfite or vinegar. Do not use a 

wire brush. If necessary, replace the flow control, o-ring on the flow control retainer, or the o-ring on the elbow.
Reset the flow control so the rounded end is visible in the flow control. Reset the white flow control retainer by pushing the 

retainer into the elbow until the o-ring seats. Remove locking clip, push down on elbow to reset and insert locking clip. 

Do not use Vaseline, oils, or other unacceptable lubricants on o-rings. A silicone lubricant may be used on the o-ring on 

the elbow or the white retainer. 

Содержание City Soft Plus XFactor Series

Страница 1: ...free service When installed in accordance with the following instructions and if given reasonable care clear soft water will be the result For servicing and future inspection purposes please file this...

Страница 2: ...Total Gallons Per Day x Grains Per Gallon of hardness Total Grains per Day INSTALLATION DATE SERIAL NUMBER INSTALLER NAME PHONE ADDRESS TABLE OF CONTENTS Job Specifications 2 Pre Installation Review...

Страница 3: ...r treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after treatment GENERAL INSTALLATION AND SERVICE WARNINGS PRE INSTALLATION REVIEW WATER...

Страница 4: ...rs are glass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o...

Страница 5: ...pes that are connected on the drain line control fitting Failure to do this could cause interior damage to the drain line flow control fitting Never insert a drain line into a drain sewer line or trap...

Страница 6: ...WITH BRINE TANK OVERFLOW GRAVITY DRAIN ONLY USED IN CASE OF MALFUNCTION IN THE BRINE SHUTOFF DO NOT CONNECT TO CONTROL VALVE DRAIN LINE IF UNIT IS INSTALLED WHERE OVERFLOW COULD CAUSE WATER DAMAGE CO...

Страница 7: ...least 1 2 full is recommended SANITIZING Use 2 oz of 5 unscented household chlorine bleach for each cubic foot of resin Pour bleach directly into the 4 diameter white brine well located inside the br...

Страница 8: ...Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the or buttons The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon...

Страница 9: ...rn to previous digit Banner Text Set the banner text up to a maximum of 44 characters Use the or to select letters of the alphabet numbers ampersand or a space in the banner text Press NEXT to forward...

Страница 10: ...Adaptor Input Voltage Hertz 120V AC 60 Hz AC Adaptor Output Voltage Current 12V AC 500 mA 3 Volt Lithium Coin Cell Battery type 2032 PC Board Relay Terminal Block DC Output Voltage 12V DC Relay Speci...

Страница 11: ...SDCS 1 A8056 Centaur Carbon for chloramine reduction in 7 LESDCS 1 6 A4074 3 4 Cu Ft 39 LBS Ion Exchange Resin for Model 7 LXD 75 1 A4074 1 Cu Ft 52 LBS Ion Exchange Resin for Model 7 LXD 100 1 A4074...

Страница 12: ...sh down to fully seat Battery replacement is 3 volt lithium coin cell type 2032 Correct Battery Orientation 1 2 3 5 6 4 X FACTOR FRONT COVER AND DRIVE ASSEMBLY After completing any valve maintenance i...

Страница 13: ...etailed service instructions 1 2 3 4 5 INJECTOR CAP INJECTOR SCREEN INJECTOR PLUG AND O RING Drawing No Order No Description Qty 1 V3005 Spacer Stack Assembly 1 2 V3004 Drive Cap Assy 1 3 V3178LP Back...

Страница 14: ...RITICAL OR HEALTH EFFECT APPLICATIONS The nut and caps are designed to be unscrewed or tightened by hand or with the service spanner wrench see page 16 If necessary a pliers can be used to unscrew the...

Страница 15: ...wing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3191 Vertical Adapter 2 INSTALLATION FITTING ASSEMBLIES 4 Water Flow Proper DLFC orient...

Страница 16: ...2 8 V3152 O ring 135 2 9 V3155 O ring 112 2 10 V3156 O ring 214 2 BYPASS VALVE Order No V3193 Although no tools are necessary to assemble or disassemble the valve the wrench shown in various position...

Страница 17: ...antity of 24 Order No V3007 09 Description Fitting 1 1 Brass Sweat Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3375 Fit...

Страница 18: ...are not fully engaged the piston rod is not in hole the wires are jammed between the drive bracket and drive back plate or the gear is not engaging the drive cap assembly To inspect the drive gears t...

Страница 19: ...embly and hand tighten the drive cap assembly Continue to tighten the drive cap assembly using a screwdriver as a ratchet until the black o ring on the spacer stack assembly is no longer visible throu...

Страница 20: ...used Sharp objects which can score the plastic should not be used to clean the injector Scoring the injector or increasing the diameter of the hole could change the operating parameters of the inject...

Страница 21: ...eter f Defective PC Board f Replace PC Board 4 Control valve regenerates at wrong time of day a Power outage a Reset time of day If PC Board has battery back up present the battery may be depleted See...

Страница 22: ...possible increase pump switch cut in to 25 psi b Incorrect injector size b Replace injector with correct size for the application c Restricted drain line c Check drain line for restrictions or debris...

Страница 23: ...NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect c Main drive gear too tight c Loosen main...

Страница 24: ...reconnect c MAV NHBP motor not fully engaged with reduction gears c Properly insert motor into casing do not force into casing Press NEXT and REGEN buttons for 3 seconds to resynchronize software wit...

Страница 25: ...PAGE 25 NOTES...

Страница 26: ...PAGE 26 A DIVISION OF C B TOOL CO 1340 MANHEIM PIKE LANCASTER PA 17601 3196 TEL 717 397 3521 FAX 717 392 0266 www lancasterwatertreatment com E mail info lancasterpump com 4 14...

Отзывы: