background image

PAGE 11

1

3

4

2

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

Drawing No. Order No.

Description

Quantity

1

H4600

3/8” Safety Brine Valve

1

2

10151

Pin

2

3

H4640-9.5 Float Assembly

1

4

H4500-48

Air Check Assembly (uncut length)

see brine tank assy for cut length

1

4740 BRINE VALVE ASSEMBLY

7

3

2

1

4

3

5

6

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

MINERAL TANK ASSEMBLY

BRINE TANK ASSEMBLY

Item 

No.

Order No.

Description

Qty

1

LXCV1 (detailed components shown in this manual)

Metered Control Valve

1

2,3,4

FG1054VTMO, D1130-12 Ft. (cut for 54 in.), R-DIP1050

Tank, Pipe, Connector, Assy for Model 7-LXD**-75

1

FG1060VTMO, D1130-12 Ft. (cut for 60 in.), R-DIP1050

Tank, Pipe, Connector, Assy for Model 7-LXD**-100

1

FG1354VTMH, D1130-12 Ft. (cut for 54 in.), R-DIP1050

Tank, Pipe, Connector, Assy for Model 7-LXD**-150

1

FG1354VTMH, D1130-12 Ft. (cut for 54 in.), R-DIP1050

Tank, Pipe, Connector, Assy for Model 7-LXD**-200

1

5

A8021

Calcite for 7-LESDNS-***

2

A8009

Carbon for 7-LESDCS-***

1

A8056

Centaur Carbon for chloramine reduction in 7-LESDCS-***

1

6

A4074 (3/4 Cu. Ft. = 39 LBS)

Ion Exchange Resin for Model  7-LXD**-75

1

A4074 (1 Cu. Ft. = 52 LBS)

Ion Exchange Resin for Model  7-LXD**-100

1

A4074 (1 1/2 Cu. Ft. = 78 LBS)

Ion Exchange Resin for Model  7-LXD**-150

1

A4074 (2 Cu. Ft. = 104 LBS)

Ion Exchange Resin for Model  7-LXD**-200

1

 

 

 

 

 

 

 

  **: CS or NS

 

 

 

 

 

 

 

  ***: 75, 100, 150, or 200

Dwg. No.

Order No.

Description

Qty

1

G2126

18x33 Brine Tank with Cover for Model 7-LXD**-75, -100, -150

1

G2136

18x40 Brine Tank with Cover for Model 7-LXD**-200

1

2

H1031

4x28 Slotted Brine Well for Model 7-LXD**-75, -100, -150

1

H1036

4x36 Slotted Brine Well for Model 7-LXD**-200

1

3

H7016

4 inch Brine Well Cap for Model 7-LXD**-75, -100, -150
(Top Cap Only for Model 7-LXD**-200)

2

(1)

4

4740

3/8” Brine Valve Assembly 

(using 1/2”x24” long air check assy for Model 7-LXD**-75, -100, -150)
(using 1/2”x32.75” long air check assy for Model 7-LXD**-200)

1

5

H1018

Two Piece Overflow Set

1

6

1640N

Nylon Screw (only for Model 7-LXD**-200)

1

6785N

Nylon Nut (only for Model 7-LXD**-200)

1

7

H1023

3/8”O.D.x6 Ft. Poly Tubing

1

Not Shown

H1072

Optional 5” High Grid Set (Only required for Model 7-LXD**-200 if Fill 

cycle factory setting is field adjusted to High: 30 LBS NaCl)

Optional

 

 

          

  **: CS or NS

 

 

              ***: 75, 100, 150, or 200

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

Содержание City Soft Plus XFactor Series

Страница 1: ...free service When installed in accordance with the following instructions and if given reasonable care clear soft water will be the result For servicing and future inspection purposes please file this...

Страница 2: ...Total Gallons Per Day x Grains Per Gallon of hardness Total Grains per Day INSTALLATION DATE SERIAL NUMBER INSTALLER NAME PHONE ADDRESS TABLE OF CONTENTS Job Specifications 2 Pre Installation Review...

Страница 3: ...r treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after treatment GENERAL INSTALLATION AND SERVICE WARNINGS PRE INSTALLATION REVIEW WATER...

Страница 4: ...rs are glass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o...

Страница 5: ...pes that are connected on the drain line control fitting Failure to do this could cause interior damage to the drain line flow control fitting Never insert a drain line into a drain sewer line or trap...

Страница 6: ...WITH BRINE TANK OVERFLOW GRAVITY DRAIN ONLY USED IN CASE OF MALFUNCTION IN THE BRINE SHUTOFF DO NOT CONNECT TO CONTROL VALVE DRAIN LINE IF UNIT IS INSTALLED WHERE OVERFLOW COULD CAUSE WATER DAMAGE CO...

Страница 7: ...least 1 2 full is recommended SANITIZING Use 2 oz of 5 unscented household chlorine bleach for each cubic foot of resin Pour bleach directly into the 4 diameter white brine well located inside the br...

Страница 8: ...Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the or buttons The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon...

Страница 9: ...rn to previous digit Banner Text Set the banner text up to a maximum of 44 characters Use the or to select letters of the alphabet numbers ampersand or a space in the banner text Press NEXT to forward...

Страница 10: ...Adaptor Input Voltage Hertz 120V AC 60 Hz AC Adaptor Output Voltage Current 12V AC 500 mA 3 Volt Lithium Coin Cell Battery type 2032 PC Board Relay Terminal Block DC Output Voltage 12V DC Relay Speci...

Страница 11: ...SDCS 1 A8056 Centaur Carbon for chloramine reduction in 7 LESDCS 1 6 A4074 3 4 Cu Ft 39 LBS Ion Exchange Resin for Model 7 LXD 75 1 A4074 1 Cu Ft 52 LBS Ion Exchange Resin for Model 7 LXD 100 1 A4074...

Страница 12: ...sh down to fully seat Battery replacement is 3 volt lithium coin cell type 2032 Correct Battery Orientation 1 2 3 5 6 4 X FACTOR FRONT COVER AND DRIVE ASSEMBLY After completing any valve maintenance i...

Страница 13: ...etailed service instructions 1 2 3 4 5 INJECTOR CAP INJECTOR SCREEN INJECTOR PLUG AND O RING Drawing No Order No Description Qty 1 V3005 Spacer Stack Assembly 1 2 V3004 Drive Cap Assy 1 3 V3178LP Back...

Страница 14: ...RITICAL OR HEALTH EFFECT APPLICATIONS The nut and caps are designed to be unscrewed or tightened by hand or with the service spanner wrench see page 16 If necessary a pliers can be used to unscrew the...

Страница 15: ...wing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3191 Vertical Adapter 2 INSTALLATION FITTING ASSEMBLIES 4 Water Flow Proper DLFC orient...

Страница 16: ...2 8 V3152 O ring 135 2 9 V3155 O ring 112 2 10 V3156 O ring 214 2 BYPASS VALVE Order No V3193 Although no tools are necessary to assemble or disassemble the valve the wrench shown in various position...

Страница 17: ...antity of 24 Order No V3007 09 Description Fitting 1 1 Brass Sweat Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3375 Fit...

Страница 18: ...are not fully engaged the piston rod is not in hole the wires are jammed between the drive bracket and drive back plate or the gear is not engaging the drive cap assembly To inspect the drive gears t...

Страница 19: ...embly and hand tighten the drive cap assembly Continue to tighten the drive cap assembly using a screwdriver as a ratchet until the black o ring on the spacer stack assembly is no longer visible throu...

Страница 20: ...used Sharp objects which can score the plastic should not be used to clean the injector Scoring the injector or increasing the diameter of the hole could change the operating parameters of the inject...

Страница 21: ...eter f Defective PC Board f Replace PC Board 4 Control valve regenerates at wrong time of day a Power outage a Reset time of day If PC Board has battery back up present the battery may be depleted See...

Страница 22: ...possible increase pump switch cut in to 25 psi b Incorrect injector size b Replace injector with correct size for the application c Restricted drain line c Check drain line for restrictions or debris...

Страница 23: ...NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect c Main drive gear too tight c Loosen main...

Страница 24: ...reconnect c MAV NHBP motor not fully engaged with reduction gears c Properly insert motor into casing do not force into casing Press NEXT and REGEN buttons for 3 seconds to resynchronize software wit...

Страница 25: ...PAGE 25 NOTES...

Страница 26: ...PAGE 26 A DIVISION OF C B TOOL CO 1340 MANHEIM PIKE LANCASTER PA 17601 3196 TEL 717 397 3521 FAX 717 392 0266 www lancasterwatertreatment com E mail info lancasterpump com 4 14...

Отзывы: