Problem

Possible Cause

Solution

14. Error – 101 = Control unable to sense motor 

movement

a. Motor not inserted full to engage pinion, 

motor wires broken or disconnected

a. Disconnect power, make sure motor is 

fully engaged, check for broken wires, 

make sure two pin connector on motor 

is connected to the two pin connection 

on the PC Board labeled MOTOR. 

Press 

NEXT

 and 

REGEN

 buttons for 

3 seconds to resynchronize software 

with piston position or disconnect 

power supply from PC Board for 5 

seconds and then reconnect.

b. PC Board not properly snapped into drive 

bracket

b. Properly snap PC Board into drive 

bracket and then Press 

NEXT

 and 

REGEN

 buttons for 3 seconds to 

resynchronize software with piston 

position or disconnect power supply 

from PC Board for 5 seconds and then 

reconnect.

c. Missing reduction gears

c. Replace missing gears

15. Error – 102 = Control valve motor ran too 

short and was unable to find the next cycle 

position and stalled

a. Foreign material is lodged in control valve a. Open up control valve and pull out 

piston assembly and seal/ stack 

assembly for inspection. Press 

NEXT

 

and 

REGEN

 buttons for 3 seconds 

to resynchronize software with piston 

position or disconnect power supply 

from PC Board for 5 seconds and then 

reconnect.

b. Mechanical binding

b. Check piston and seal/ stack assembly, 

check reduction gears, check drive 

bracket and main drive gear interface. 

Press 

NEXT

 and 

REGEN

 buttons for 

3 seconds to resynchronize software 

with piston position or disconnect 

power supply from PC Board for 5 

seconds and then reconnect.

c. Main drive gear too tight

c. Loosen main drive gear. Press 

NEXT

 

and 

REGEN

 buttons for 3 seconds 

to resynchronize software with piston 

position or disconnect power supply 

from PC Board for 5 seconds and then 

reconnect.

d. Improper voltage being delivered to PC 

Board

d. Verify that proper voltage is being 

supplied. Press 

NEXT

 and 

REGEN

 

buttons for 3 seconds to resynchronize 

software with piston position or 

disconnect power supply from 

PC Board for 5 seconds and then 

reconnect.

16. Error – 103 = Control valve motor ran too 

long and was unable to find the next cycle 

position

a. Motor failure during a regeneration

a. Check motor connections then Press  

NEXT

 and 

REGEN

 buttons for 3 

seconds to resynchronize software 

with piston position or disconnect 

power supply from PC Board for 5 

seconds and then reconnect.

b. Foreign matter built up on piston and 

stack assemblies creating friction and 

drag enough to time out motor

b. Replace piston and stack assemblies. 

Press 

NEXT

 and 

REGEN

 buttons for 

3 seconds to resynchronize software 

with piston position or disconnect 

power supply from PC Board for 5 

seconds and then reconnect.

c. Drive bracket not snapped in properly 

and out enough that reduction gears and 

drive gear do not interface

c. Snap drive bracket in properly then 

Press 

NEXT

 and 

REGEN

 buttons for 

3 seconds to resynchronize software 

with piston position or disconnect 

power supply from PC Board for 5 

seconds and then reconnect.

Содержание City Soft Plus XFactor Series

Страница 1: ...free service When installed in accordance with the following instructions and if given reasonable care clear soft water will be the result For servicing and future inspection purposes please file this...

Страница 2: ...Total Gallons Per Day x Grains Per Gallon of hardness Total Grains per Day INSTALLATION DATE SERIAL NUMBER INSTALLER NAME PHONE ADDRESS TABLE OF CONTENTS Job Specifications 2 Pre Installation Review...

Страница 3: ...r treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after treatment GENERAL INSTALLATION AND SERVICE WARNINGS PRE INSTALLATION REVIEW WATER...

Страница 4: ...rs are glass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o...

Страница 5: ...pes that are connected on the drain line control fitting Failure to do this could cause interior damage to the drain line flow control fitting Never insert a drain line into a drain sewer line or trap...

Страница 6: ...WITH BRINE TANK OVERFLOW GRAVITY DRAIN ONLY USED IN CASE OF MALFUNCTION IN THE BRINE SHUTOFF DO NOT CONNECT TO CONTROL VALVE DRAIN LINE IF UNIT IS INSTALLED WHERE OVERFLOW COULD CAUSE WATER DAMAGE CO...

Страница 7: ...least 1 2 full is recommended SANITIZING Use 2 oz of 5 unscented household chlorine bleach for each cubic foot of resin Pour bleach directly into the 4 diameter white brine well located inside the br...

Страница 8: ...Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the or buttons The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon...

Страница 9: ...rn to previous digit Banner Text Set the banner text up to a maximum of 44 characters Use the or to select letters of the alphabet numbers ampersand or a space in the banner text Press NEXT to forward...

Страница 10: ...Adaptor Input Voltage Hertz 120V AC 60 Hz AC Adaptor Output Voltage Current 12V AC 500 mA 3 Volt Lithium Coin Cell Battery type 2032 PC Board Relay Terminal Block DC Output Voltage 12V DC Relay Speci...

Страница 11: ...SDCS 1 A8056 Centaur Carbon for chloramine reduction in 7 LESDCS 1 6 A4074 3 4 Cu Ft 39 LBS Ion Exchange Resin for Model 7 LXD 75 1 A4074 1 Cu Ft 52 LBS Ion Exchange Resin for Model 7 LXD 100 1 A4074...

Страница 12: ...sh down to fully seat Battery replacement is 3 volt lithium coin cell type 2032 Correct Battery Orientation 1 2 3 5 6 4 X FACTOR FRONT COVER AND DRIVE ASSEMBLY After completing any valve maintenance i...

Страница 13: ...etailed service instructions 1 2 3 4 5 INJECTOR CAP INJECTOR SCREEN INJECTOR PLUG AND O RING Drawing No Order No Description Qty 1 V3005 Spacer Stack Assembly 1 2 V3004 Drive Cap Assy 1 3 V3178LP Back...

Страница 14: ...RITICAL OR HEALTH EFFECT APPLICATIONS The nut and caps are designed to be unscrewed or tightened by hand or with the service spanner wrench see page 16 If necessary a pliers can be used to unscrew the...

Страница 15: ...wing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3191 Vertical Adapter 2 INSTALLATION FITTING ASSEMBLIES 4 Water Flow Proper DLFC orient...

Страница 16: ...2 8 V3152 O ring 135 2 9 V3155 O ring 112 2 10 V3156 O ring 214 2 BYPASS VALVE Order No V3193 Although no tools are necessary to assemble or disassemble the valve the wrench shown in various position...

Страница 17: ...antity of 24 Order No V3007 09 Description Fitting 1 1 Brass Sweat Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3375 Fit...

Страница 18: ...are not fully engaged the piston rod is not in hole the wires are jammed between the drive bracket and drive back plate or the gear is not engaging the drive cap assembly To inspect the drive gears t...

Страница 19: ...embly and hand tighten the drive cap assembly Continue to tighten the drive cap assembly using a screwdriver as a ratchet until the black o ring on the spacer stack assembly is no longer visible throu...

Страница 20: ...used Sharp objects which can score the plastic should not be used to clean the injector Scoring the injector or increasing the diameter of the hole could change the operating parameters of the inject...

Страница 21: ...eter f Defective PC Board f Replace PC Board 4 Control valve regenerates at wrong time of day a Power outage a Reset time of day If PC Board has battery back up present the battery may be depleted See...

Страница 22: ...possible increase pump switch cut in to 25 psi b Incorrect injector size b Replace injector with correct size for the application c Restricted drain line c Check drain line for restrictions or debris...

Страница 23: ...NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect c Main drive gear too tight c Loosen main...

Страница 24: ...reconnect c MAV NHBP motor not fully engaged with reduction gears c Properly insert motor into casing do not force into casing Press NEXT and REGEN buttons for 3 seconds to resynchronize software wit...

Страница 25: ...PAGE 25 NOTES...

Страница 26: ...PAGE 26 A DIVISION OF C B TOOL CO 1340 MANHEIM PIKE LANCASTER PA 17601 3196 TEL 717 397 3521 FAX 717 392 0266 www lancasterwatertreatment com E mail info lancasterpump com 4 14...

Отзывы: