91
EN
&RG05HY
,'2/$6:7
NOTE
For the dismantling of the paneling and for normal maintenance activities
the minimum operating spaces must be respected.
Select an installation location where the following conditions are met:
- Place that allows to respect the maximum lengths allowed for pipes, connections
to the unit of temperature probes, remote control etc ..
- Do not place objects or equipment on top of the unit.
0DNHVXUHWKDWDOOWKHSUHFDXWLRQVDQGSUHVFULSWLRQVIRUHVHHQE\ORFDOODZVDQG
UHJXODWLRQVUHJDUGLQJSRVVLEOHUHIULJHUDQWOHDNVDUHFRUUHFWO\DSSOLHG
≥
300
≥
300
≥
50
≥
1200
≥ 700
fig. 9 - minimum operating area for indoor unit
CAUTION
The indoor unit should be installed in an indoor water proof place, or the safety of the unit and the operator cannot be ensured.
•
The indoor unit is to be wall mounted in an indoor location that meets the following requirements:
•
The installation location is frost-free.
•
The space around the unit is adequate for serving, see fig. 9.
•
The space around the unit allows for sufficient air circulation.
•
There is a provision for pressure relief valves blow-off.
CAUTION
:KHQWKHXQLWUXQQLQJLQWKHFRROLQJPRGHFRQGHQVDWHPD\GURSIURPWKHZDWHULQOHWDQGZDWHURXWOHWSLSHV3OHDVHPDNHVXUHWKHGURS
-
ping condensate will not result in damage of your furniture and other devices.
•
The installation surface is a flat and vertical non-combustible wall, capable of supporting the operation weight of the unit.
•
All piping lengths and distance have been taken into consideration.
8.2 Minimum plant water content
Indoor unit technical data
-
UM
0LQLPXPSODQWZDWHUFRQWHQW
l