2. OPERATING INSTRUCTIONS
2.1 Introduction
Dear Customer,
FL D LN C
is a high-efficiency for heating and hot water production running on natural
gas or LPG, and equipped with a microprocessor control system.
2.2 Control panel
Panel
fig. 1 - Control panel
Key of panel fig. 1
1
DHW temperature setting decrease button
2
DHW temperature setting increase button
3
Heating system temperature setting decrease button
4
Heating system temperature setting increase button
5
Display
6
"Sliding Temperature" Menu - Summer/Winter mode selection - Reset button
7
Unit On/Off - Economy/Comfort mode selection button
8
DHW symbol
9
DHW mode
10
Summer mode
11
Multifunction
12
Eco (Economy) mode
13
Heating
14
Heating symbol
15
Burner lit and actual power level (flashing during combustion fault function)
16
Service Tool connection
17
Water gauge
Indication during operation
Heating
A heating demand (generated by the Room Thermostat or Remote Timer Control) is in-
dicated by flashing of the hot air above the radiator on the display.
The display (detail 11 - fig. 1) shows the actual heating delivery temperature and, during
heating standby time, the message
“d2”
.
In the event of continuous
"d2"
messages, reduce parameter
P01
(ignition power - ““tS”
- Transparent Parameters Menu” on page 22) to a minimum of 9.
Domestic hot water (DHW)
A DHW demand (generated by drawing domestic hot water) is indicated by flashing of
the hot water under the tap on the display.
The display (detail 11 - fig. 1) shows the actual DHW outlet temperature and, during
DHW standby time, the message
“d1“
.
Comfort
A Comfort demand (reinstatement of temperature inside the boiler) is indicated by flash-
ing of the water under the tap on the display. The display (detail 11 - fig. 1) shows the
actual temperature of the water in the boiler.
Fault
In case of a fault (see cap. 4.4) the display shows the fault code (detail 11 - fig. 1) and
during safety pause times the messages
“d3”, “d4”
and
“d5”
.
2.3 Lighting and shutdown
Connection to the power supply
•
During the first 5 seconds the display will also show the card software release.
•
Open the gas cock ahead of the boiler.
•
The boiler is now ready to function automatically whenever domestic hot water is
drawn or in case of a heating demand (generated by Room Thermostat or Remote
Temperature Control).
Turning the boiler off and on
Press the
on/off
button (detail 7 - fig. 1) for 5 seconds.
fig. 2 - Turning the boiler off
When the boiler is turned off, the circuit board is still powered. Domestic hot water and
heating are disabled. The frost protection system remains activated. To relight the boiler,
press the
on/off
button (detail 7 fig. 1) again for 5 seconds.
fig. 3
The boiler will be immediately ready to work whenever domestic hot water is drawn or in
case of a heating demand (generated by the Room Thermostat or the Remote Timer
control).
B
The frost protection system does not work when the pow-
er and/or gas to the unit are turned off. To avoid damage
caused by freezing during long shutdowns in winter, it is
advisable to drain all water from the boiler, the DHW cir-
cuit and the heating system water; or drain just the DHW
circuit and add a suitable antifreeze to the heating sys-
tem, as prescribed in sec. 3.3.
2.4 Adjustments
Summer/Winter Switchover
Press the
summer/winter
button (detail 6 - fig. 1) for 2 seconds.
The display activates the Summer symbol (detail 10 - fig. 1): the boiler will only deliver
domestic hot water. The antifreeze system remains activated.
To deactivate the Summer mode, press the
summer/winter
button (detail 6 - fig. 1)
again for 2 seconds.
Heating temperature adjustment
Use the heating buttons (details 3 and 4 - fig. 1) to adjust the temperature from a min. of
30°C to a max. of 80°C; in any case, it is advisable not to operate the boiler below 45°C.
fig. 4
DHW temperature adjustment
Use the DHW buttons (details 1 and 2 - fig. 1) to adjust the temperature from a min. of
40°C to a max. of 55°C.
fig. 5
Room temperature adjustment (with optional room thermostat)
Using the room thermostat, set the temperature required in the rooms. If the room ther-
mostat is not installed, the boiler will keep the system at the set system delivery setpoint
temperature.
Room temperature adjustment (with optional remote timer control)
Using the remote timer control, set the required temperature in the rooms. The boiler will
adjust the system water according to the required room temperature. For operation with
remote timer control, please refer to the relevant instruction manual.
ECO/COMFORT selection
The unit has a function that ensures a high domestic hot water delivery speed and max-
imum comfort for the user. When the device is activated (COMFORT mode), the water
contained in the boiler is kept hot, thereby ensuring immediate availability of hot water
on opening the tap, without waiting times.
The user can deactivate the device (ECO mode) by pressing the
eco/comfort
button
(detail 7 - fig. 1). In ECO mode the display activates the ECO symbol (detail 12 - fig. 1).