25
The scale is very fine and has a complete range of +2mm (0.08")
–
2mm (0.08").
Adjust the platen as follows.
1.
Loosen the clamp.
2.
Move the platen with the adjusting handle to the required setting.
3.
Re-clamp.
Note.
When not using the sander for finishing cuts, move the platen to the maximum
negative position.
Testing the machine
Note.
Remove all tools and other materials from the machine prior to testing it.
1.
Plug in the electrical supply.
2.
Switch on the sanding machine momentarily. Check that the sanding belt is running
true and balanced on the rollers.
3
. If the belt is not running true, adjust the belt (detailed later in the manual).
4.
If the belt is running true and balanced on the rollers, switch on the machine and
allow the machine to run for a few minutes.
5.
While the machine is running, check for rattles and vibration. If rattles or vibration are
detected, investigate the cause and tighten the relevant parts.
Scale
Adjusting handle
Clamp