Wiring:
Finish electrical connection according to the
electrical drawings.
The wirings on the spot should refer to the
requirements of Clause 13 (Wring practices) of EN
60204-1:2006.
Checking:
After finishing wiring on the spot, check the
following items at least:
Check the wirings of machine.
Check the direction of motors and change wiring if
necessary.
Check the components for defects, such as
loosening or damage.
Check the functions of safety devices
Change
the
Connections
From
220V/3PH to 380V/3PH.
This model can be rewired
from 220V/3PH to
380V/3PH
operation,
this
procedure
takes
moderate electrical skill and the rewiring job must
be inspected by a qualified electrician before the
saw is connected to the power source.