Adjustment of reduced flowrate of surface burners:
After connection or change of gas, it is
crucial
to modify this
adjustment.
- Remove the control knob. Light the burner, adjust to minimum
setting, then use a small screwdriver to set the adjusting screw
J
(Figure 23).
Note
: Flame is reduced to 1/4 of its size in the minimum setting,
the burner must remain lit when changing from maximum setting
to minimum setting.
Refitting the cooking surface :
When refitting the cooking surface, it is vital to tighten fastening
screws (figures 13, 14 and 15). Failure to do so can cause
distortion of the cooktop.
OVEN BURNERS:
Disassembling of the gas oven burner:
-
Withdraw the baseplate (Fig.24).
CAUTION:
when refitting, slide the baseplate underneath the lip at the oven front
(fig.25).
-Unscrew screw
K
holding the burner (Fig.26).
-Remove the drawer.
-Loosen the set screw
L
(Fig.27).
-Push the burner towards the back of the oven cavity and lift to raise and release it.
Oven Burner Injector:
-
Remove the baseplate,
CAUTION:
when refitting, slide the
baseplate underneath the lip at the oven front (Fig. 24 & 25).
-Remove the screen under the oven floor by removing the two
screws at the oven front, the screen rests on two pins at the
rear, pull screen forward to remove through the drawer cavity.
-Loosen screw
L
that holds the air collar and pull the air collar
forward to gain aces to the injector.
-Remove 12mm hex injector and replace with the new one.
Page 13 of 38 – US – Date: 26/02/10
Fig. 23
J
Fig. 25
Fig. 24
Fig. 26
K
Fig. 27
M
Fig. 28
L