20
8) SAFETY SENSORS
This section describes how to connect and setup correctly some of the safety sensors compliant with the standard EN12987 available on
the market, to ensure a safety level which corresponds to PL = c, Category 2 as provided for by the standard EN16005.
8.1) SAFETY SENSOR OA-EDGE T
This section describes how to connect and setup the safety sensors in accordance with the standard EN16005.
WIRING CONNECTION OF SENSOR OA-EDGE T
CONNECTION OF AUTOMATION NEXT 120S WIRING
Wiring between the sensor and the terminal of the control unit NEXT-L120S
1. WHITE
(+)
Power supply
TERMINAL 24 (+)
2. BROWN
(‑)
Power supply
TERMINAL 0 (‑)
3. GREEN
COM (Closing side)
TERMINAL 0 COM
4. YELLOW
N.C. (Closing side)
TERMINAL
7
Closing safety sensor
5. GREY
N.O. (Closing side)
do not connect
6. PINK
COM (Opening side)
TERMINAL 0 COM
7. BLUE
N.C. (Opening side)
TERMINAL
6
Opening safety sensor
8. RED
N.O. (Opening side)
do not connect
9. BLACK
(+)
Test input
TERMINAL T TEST(+)
10. VIOLET
(‑)
Test input
TERMINAL
0
GND (‑)
DIP SWITCH SETTING ON OA-EDGE T
PARAMETERS ON DIGITAL SELECTOR ET-DSEL
A7 = ON
Low level test input.
A8 = OFF
Input test delay 10msec.
B4 = OFF
Sensor installed on opening side.
B4 = ON
Sensor installed on closing side.
F11 (S05) = ON
Closing safety sensor
F12 (S06) = ON
Opening safety sensor
F13 (S07) = ON
TEST of opening safety sensor
F14 (S08) = ON
TEST of opening safety sensor
F15 (S09) = OFF
Test level LOW
8.2) FLAT SCAN SAFETY SENSOR
CONNECTION OF FLAT SCAN SENSOR WIRING
CONNECTION OF AUTOMATION NEXT 120S WIRING
Wiring between the sensor and the terminal of the control unit NEXT-L120S
1. GREEN
(+)
Power supply
TERMINAL 24 (+)
2. BROWN
(‑)
Power supply
TERMINAL 0 (‑)
3. YELLOW
COM (Opening side)
TERMINAL 0 COM
4. WHITE
N.C. (Opening side)
TERMINAL
6
Opening safety sensor
5. PINK
COM (Closing side)
TERMINAL 0 COM
6. GREY
N.C. (Closing side)
TERMINAL
7
Closing safety sensor
7. RED
(+)
Test input
TERMINAL T TEST(+)
8. BLUE
(‑)
Test input
TERMINAL
0
GND (‑)
DIP SWITCH SETTING ON FLAT SCAN
PARAMETERS ON DIGITAL SELECTOR ET-DSEL
DIP 1 ON
Sensor installed on opening side.
DIP 1 OFF
Sensor installed on closing side.
F11 (S05) = ON
Closing safety sensor
F12 (S06) = ON
Opening safety sensor
F13 (S07) = ON
TEST of opening safety sensor
F14 (S08) = ON
TEST of opening safety sensor
F15 (S09) = OFF
Test level LOW
Содержание NEXT 120s
Страница 2: ......
Страница 11: ...11 X 36mm X 6 mm 6 2 SLIDING PUSH ARM NEXT120 BDS STANDARD TAPERED PIN NEXT EXT EXTENSION TAPERED PIN ...
Страница 12: ...12 x X 36mm X 6 mm 6 3 ARTICULATED PUSH ARM NEXT120 BAS STANDARD TAPERED PIN NEXT EXT EXTENSION TAPERED PIN ...
Страница 13: ...13 X 91mm X mm 6 4 ELBOW SLIDING PULL ARM NEXT120 B150 STANDARD TAPERED PIN NEXT EXT EXTENSION TAPERED PIN ...
Страница 14: ...14 X 91mm X mm 6 5 ELBOW SLIDING PULL ARM NEXT120 B250 STANDARD TAPERED PIN NEXT EXT EXTENSION TAPERED PIN ...
Страница 62: ...62 ...
Страница 63: ...63 ...