19
Terminals 0-5
AUX 1 (manual switch)
Terminals 0-4
AUX 2 (manual switch)
Terminals 0-3
OPEN input (N.O. contact if F21 = ON; N.C. contact if F21 = OFF)
Terminals 0-2
internal radar input (N.O. contact)
Terminals 0-1
external radar input (N.O. contact)
Terminals 0-6
input of opening safety sensor (N.C. contact)
Terminals 0-7
input of closing safety sensor (N.C. contact)
Terminals 0-24
24Vdc output (0 negative, 24V positive)
Terminals 0-T
Test for safety sensors (0 negative, T positive)
Terminals S-24V
Open Collector output.
The mode of operation depends on the multi-function F41m.
Terminals C - NO - NC
(Common, normally open, normally closed)
Potential free contact of relay RL1 to connect the electric lock.
ELECTRICAL CONNECTIONS OF NEXT-L120S CONTROL UNIT TERMINALS