84
|
i
•
FeedGood
L
• Technical Guide
Calibration by Actual Weight
This is to calibrate the scale when the mixing wagon is full and
you cannot unload it.
1.
To execute the Calibration, select the item “CAL. by ACTUAL
WEIGHT”, then press
u
.
The display shows the message “Do you want to execute the
Calibration?”.
2.
Press
OK
to confirm.
The display shows the message “Enter the value.” and after 3
seconds the value of the actual weight.
3.
Press
u
to program the value.
The display shows the icon
.
4.
Set the weight, then press
OK
.
The display shows the message "Calibration in progress.
Wait...” and at the end the message “Calibration executed
correctly.”.
Calibration by Load Cells Code
This is to calibrate the scale when it is connected to the load cells
listed in Table 1.
1.
To execute the Calibration, select the item “CAL. by LOAD
CELLS CODE”, then press
u
.
The display shows the message “Do you want to execute the
Calibration?”.
2.
Press
OK
to confirm.
The display shows the message “Set the parameters and
press OK.” and after 3 seconds the previously set
parameters.
3.
Set the load cells code, then press
OK
.
4.
Set the number of load cells, then press
OK
.
5.
Press
OK
to confirm the Calibration.
The display shows the message "Calibration in progress.
Wait...” and at the end the message “Calibration executed
correctly.”.
Содержание I Feed Good L
Страница 1: ... i FeedGood L Weighing System Technical Guide ...
Страница 2: ... ...
Страница 13: ...i FeedGood L Technical Guide 11 Connection diagram base version ...
Страница 14: ...12 i FeedGood L Technical Guide Connection diagram with wired Remote Terminal and CAN Bus Port ...
Страница 15: ...i FeedGood L Technical Guide 13 Connection diagram with wireless Remote Terminal ...
Страница 128: ... ...
Страница 129: ... ...
Страница 130: ... ...