4-20mA Analogue Output
This is for setting the operating parameters of the "4-20mA
Analogue Output" option.
If the scale is supplied with the “4-20mA Analogue Output” option,
on the Weighing it gives an analogue signal proportional to the
Total Weigh on the
4-20mA
connector.
Note
: the Preference is only displayed if the scale is supplied with
the "4-20mA Analogue Output" option.
Note
: when the scale is supplied with the "4-20mA Analogue
Output" option, the maximum power supply of the scale must be
limited to 30Vdc.
Note
: for more information refer to the documentation attached to
the “4-20mA Analogue Output” option or contact the Customer
Service.
Display: 4-20mA
Options:
•
4-20mA F.S.:
100 … 99,999 kg/lb (
1,000
).
•
HYSTERESIS: -1,000 …
0
.
Welcome Message
This is to program the message you want to display at Power On.
The message must have a maximum of 2 rows with 20
alphanumerical characters each.
Display: WELCOME MESS.
Default: LABEL ADVANCED SOLUTIONS
Buzzer
This is to enable operation of the buzzer when you press a key or
during Weighing to indicate that the Prealarm Threshold has been
reached or any alarms.
Display: BUZZER
Options:
•
KEYPAD:
No
, Yes.
•
WEIGHING:
No
, Yes.
Содержание I Feed Good L
Страница 1: ... i FeedGood L Weighing System Technical Guide ...
Страница 2: ... ...
Страница 13: ...i FeedGood L Technical Guide 11 Connection diagram base version ...
Страница 14: ...12 i FeedGood L Technical Guide Connection diagram with wired Remote Terminal and CAN Bus Port ...
Страница 15: ...i FeedGood L Technical Guide 13 Connection diagram with wireless Remote Terminal ...
Страница 128: ... ...
Страница 129: ... ...
Страница 130: ... ...