LAARS Heating Systems
Page 58
5.5 CH Set Point Change Mode
CH Set point Change Mode
Indicate
Indicator
Current CH Temperature Set-Point
Celsius or Fahrenheit
or
If Communication state is activated
If flame is detected
Date and Time indicator
If CH pump is operating
If there currently a Demand for Central Heat (CH)
Default CH set-point is 180°F (82°C)
CH set-point range is 86°F ~180°F (30.0°C ~ 82.0°C)
To change CH Setpoint,
press the C
button. The CH Icon and current
CH Setpoint will flash.
Turn the E dial clockwise to increase, and counterclockwise to decrease CH setpoint, until
desired temperature is reached.
Press E dial to save changes and to Exit.