background image

 

 
 

 

 

7. LCD 

Overview 

8. Function 

test: 

 

Once the weather station is powered up, perform a function test by 
checking that the weather data is received.  To do this, press the 
DISPLAY, PRESSURE or WIND keys to toggle through the relevant 
LCD sections: 

The following illustration shows the full segments of the LCD for 
description purposes only and will not appear like this during 
normal operation and use. 

 

 

 

1) Indoor 

temperature and humidity 

 

2) Outdoor 

temperature and humidity 

 

3)  Outdoor wind chill 

 
 

4) Dew 

point 

 

5)  Rainfall 24 hour 

 

6) Rainfall 

1hour 

 

7) Rainfall 

Total 

 
 

8)  Relative and absolute pressure 

 

9)  Wind speed, wind direction and wind direction in degrees 

 

 

 

If any readings cannot be received from the sensors, lines (- - -) will 
be displayed in the respective weather sections of the LCD.  In this 
case, check that all cables are correctly inserted into the correct 
sockets and/or check the batteries in the outdoor thermo/hygro 
sensor and press and hold the PLUS (+) key for 2 seconds and a 
short beep will sound to synchronize the base station to the sensors 
otherwise no weather data will be received. 

 
 
 
 
 
 
 
 
 

 

 

Some weather readings such as wind speed and direction may not 
appear immediately on the LCD if the wind-fan or vane of the wind 
sensor is moved.  This is due to the set reading time intervals for the 
wind readings.  However the current wind speed or direction will be 
displayed once the time reading interval is reached.  For rainfall, the 
interval readings may take up to 2 minutes before the data is 
displayed on the LCD. 

 
 
 
 
 
 
 

15.  24h, 1h or total hour display 
16.  Humidity display as RH% 
17.  Rainfall units (inch or mm) 
18.  Temperature display units (ºC or ºF) 
19.  Outdoor temperature/humidity display
20.  Indoor temperature/humidity display 
21.  Dew point temperature display 
22.  Wind chill temperature display 
23.  Wind alarm icon 
24.  Wind information for Min/Max speed 

and wind speed low, high, direction 
alarm 

25.  Wind direction and speed (m/s, knots, 

Beaufort, km/h or mph) display  

26.  Alarm buzzer ON/OFF icon 
27.  General alarm icon 

1.  Low battery indicator 
2.  WWVB radio controlled time icon 
3. Date 

display 

4.  Time zone display 
5.  Date, seconds, alarm time and time 

zone 

6. Alarm 

icon 

7.  Weather forecast icons 
8.  Weather tendency indicator 
9.  Pressure alarm display 
10.  hPa/inHg air pressure unit 
11.  Pressure units (relative or absolute) 
12.  433MHz reception icon 
13. Rainfall display 
14.  Indoor, outdoor, humidity, dew point, 

wind chill, rainfall alarm icon 

 

 
 

 

 
 

9. Mounting 

 

 

27

26 

25 

24 

18

21 

22 

20 

19 

11 

23

17

15

10

13

14

12

16

 

Important Note 

 
 

Prior to drilling mounting holes and permanently affixing any of the 
units, please ensure the following points are considered: 

 
 

• 

Cable lengths of the units meet with your distance requirements 
at the point of fixing 

 
 
 

Содержание WS-2310

Страница 1: ...10 Resetting factory settings 11 Function description 12 Operation keys 13 Basic programming modes 14 MIN MAX programming modes 15 Alarm programming modes 16 Auto memory for stored values 17 Accessor...

Страница 2: ...wind and rain sensors are connected to the thermo hygro sensor for operating power and rely on it to communicate to the base station Weather data sent from the thermo hygro sensor can be done by wire...

Страница 3: ...the data to the base station Operating power is taken from the thermo hygro sensor using a 32ft cable connection Features of Rain sensor The rain sensor measures the rainfall and sends the data to the...

Страница 4: ...hree sockets for the wind sensor rain sensor and the base station 2 Connect the attached cables of wind and rain sensors to the corresponding sockets of the thermo hygro sensor by clicking them into p...

Страница 5: ...ection for power back up in case of AC power failure A loss of power would desynchronize the base station and the sensor and no weather data will be received To Synchronize the units so that the weath...

Страница 6: ...time intervals for the wind readings However the current wind speed or direction will be displayed once the time reading interval is reached For rainfall the interval readings may take up to 2 minute...

Страница 7: ...ignals are received the system can be affixed Also if you have selected to use cable connection ensure that distances can reach all desired locations before affixing any unit permanently Once the wind...

Страница 8: ...gro Sensor However if you wish to make a full reset of the base station and return to the original factory settings simultaneously press and hold the PRESSURE and WIND keys for about 5 seconds The bas...

Страница 9: ...e displayed in different sections on the LCD If this is not the case please observe the notes on Interferences below Sunny Rainy Cloudy Notes to hPa sensitivity setting for weather forecasting The hPa...

Страница 10: ...chill Outdoor dew point Rainfall 24h Rainfall 1h Rainfall total Notes to Dewpoint and Windchill Air can at a certain temperature only carry a certain amount of water water vapor which also increases a...

Страница 11: ...current maximum minimum display modes Indoor temperature and humidity Outdoor temperature and humidity Outdoor wind chill Outdoor dew point Rainfall 24h 1h total WIND key To toggle between the followi...

Страница 12: ...the manually set time and date and no further reception is attempted until the following day The manual setting takes the user through the following modes 1 8 level LCD contrast setting default level...

Страница 13: ...Setting Alarms For alarm setting press the ALARM key once while in normal operation mode to enter the normal alarm time and by further pressing the ALARM key will toggle through each of the alarm mode...

Страница 14: ...reach the indoor humidity high alarm set mode 3 Press and hold the SET key to enter the indoor humidity high setting values digits will start flashing and set the desired indoor humidity high by usin...

Страница 15: ...time alarm 2 Continue to press the ALARM key until you reach the rain 1 hour alarm set mode 3 Press and hold the SET key to enter the rain setting values digits will start flashing and set the desire...

Страница 16: ...Alarm BUZZER OFF The time and all the weather alarms may have buzzer sound set to OFF by holding the MINUS key down for about 3 seconds in normal display mode and the BUZZER OFF icon appears on the b...

Страница 17: ...75 2 F with a pre set hysteresis of 1 8 F so that the alarm can be produced again Hysteresis values for the various weather data types are given in the following table For your convenience additional...

Страница 18: ...the low battery indicator will light up on the LCD Please participate in the preservation of the environment by properly disposing of all used up batteries and accumulators at designated disposal poi...

Страница 19: ...n the housing and screen of the base station only with a soft damp cloth Do not use abrasives or solvents Ensure that the rain sensor does not collect leaves or other dirt by checking the funnel for b...

Страница 20: ...of 30 000 ft is around 8 85 inHg Resolution 0 01 inHg Relative humidity checking interval every 30 seconds Alarm duration 2 minutes approx Power consumption Base Station Batteries 3 x AA IEC LR6 1 5V...

Отзывы: