background image

Alarm Modes 

• 

Indoor temperature

 (max or min with time and date) 

• 

Indoor humidity

 (max or min with time and date) 

As well as the normal time alarm, this feature will allow users to set a 
range of specific alarms to meet specific weather and temperature 
conditions set by the user.  The weather station allows for the 
following 13 alarms modes to be set: 

• 

Outdoor temperature

 (max or min with time and date) 

• 

Outdoor humidity

 (max or min with time and date) 

• 

Outdoor wind chill

 (max or min with time and date) 

• 

Outdoor dew point

 (max or min with time and date) 

 

• 

Rainfall 24 hours

 (max or min with time and date) 

1. Time 

alarm 

• 

Rainfall 1 hour

 (max or min with time and date) 

2.  Indoor temperature high alarm and low alarm 

• 

Rainfall total

 (max only with time and date)

 

3.  Outdoor temperature high alarm and low alarm 

 

4.  Indoor humidity high alarm and low alarm 

When in any of the above modes, press the MIN/MAX key to toggle 
between the maximum or minimum values of those records and their 
respective time and dates will also be shown.  

5.  Outdoor humidity high alarm and low alarm 
6.  Wind chill high alarm and low alarm 
7.  Dew point alarm high alarm and low alarm 

 

8.  Rainfall 24h alarm 

For the wind and pressure minimum and maximum readings, the 
same would apply except that the WIND or PRESSURE keys would 
be used instead of the DISPLAY KEY. 

9.  Rainfall 1h alarm 
10.  Pressure high alarm and low alarm 
11.  Wind speed high alarm and low alarm 

 

12.  Wind direction alarm 

Exiting the MIN/MAX modes 

13.  Storm warning alarm 

If the maximum and minimum modes with times and dates are 
displayed, press the PLUS (+) key twice to return the normal display 
mode.   

 

Setting Alarms: 

For alarm setting, press the ALARM key once while in normal 
operation mode to enter the normal alarm time and by further 
pressing the ALARM key will toggle through each of the alarm modes: 

 

Resetting the MIN/MAX records 

While in the minimum or maximum mode, the time and dates are also 
displayed along with the recorded values.  If the MINUS (-) key is 
pressed while any of these values are displayed, that particular 
minimum or maximum record will be reset to current reading together 
with the current time and date with the exception of the following: 

  

Note: 
The alarm icon will automatically appear upon pressing the SET 
key to tell the user the alarm is activated. Further pressing the 
SET key will deactivate/reactivate the alarm. 

 

The first case is Rainfall Total, which has neither maximum nor 
minimum records since it will show only the total rainfall. Pressing 
the MINUS (-) key will reset the rainfall total value to zero and the 
time recording to current time. 

 

Time alarm setting 

1)  Press the ALARM key to enter the normal time alarm 
2)  Press and hold the SET key to enter the alarm hour time set 

mode (the hour digits will flash) and set the desired hour by using 
the PLUS (+) or MINUS (-) keys 

 

The second case is Rainfall 24h or 1h, which records maximum 
rain count only for these respective times. Pressing the MINUS (-
) key in either of these two modes will reset the rain count to the 
current rain count and time and date.  

3)  Press the SET key to enter the alarm minute time set mode (the 

minutes digits will flash) and set the desired minutes using the 
PLUS (+) or MINUS (-) keys 

 

The third case is wind speed, which will only reset the recorded 
time to current time when the MINUS (-) key is pressed.

 

4)  Press ALARM key to confirm followed by the MIN/MAX key to 

return to the normal display mode. 

 

15. 

Alarm Programming Modes 

 

 

Содержание WS-2310

Страница 1: ...10 Resetting factory settings 11 Function description 12 Operation keys 13 Basic programming modes 14 MIN MAX programming modes 15 Alarm programming modes 16 Auto memory for stored values 17 Accessor...

Страница 2: ...wind and rain sensors are connected to the thermo hygro sensor for operating power and rely on it to communicate to the base station Weather data sent from the thermo hygro sensor can be done by wire...

Страница 3: ...the data to the base station Operating power is taken from the thermo hygro sensor using a 32ft cable connection Features of Rain sensor The rain sensor measures the rainfall and sends the data to the...

Страница 4: ...hree sockets for the wind sensor rain sensor and the base station 2 Connect the attached cables of wind and rain sensors to the corresponding sockets of the thermo hygro sensor by clicking them into p...

Страница 5: ...ection for power back up in case of AC power failure A loss of power would desynchronize the base station and the sensor and no weather data will be received To Synchronize the units so that the weath...

Страница 6: ...time intervals for the wind readings However the current wind speed or direction will be displayed once the time reading interval is reached For rainfall the interval readings may take up to 2 minute...

Страница 7: ...ignals are received the system can be affixed Also if you have selected to use cable connection ensure that distances can reach all desired locations before affixing any unit permanently Once the wind...

Страница 8: ...gro Sensor However if you wish to make a full reset of the base station and return to the original factory settings simultaneously press and hold the PRESSURE and WIND keys for about 5 seconds The bas...

Страница 9: ...e displayed in different sections on the LCD If this is not the case please observe the notes on Interferences below Sunny Rainy Cloudy Notes to hPa sensitivity setting for weather forecasting The hPa...

Страница 10: ...chill Outdoor dew point Rainfall 24h Rainfall 1h Rainfall total Notes to Dewpoint and Windchill Air can at a certain temperature only carry a certain amount of water water vapor which also increases a...

Страница 11: ...current maximum minimum display modes Indoor temperature and humidity Outdoor temperature and humidity Outdoor wind chill Outdoor dew point Rainfall 24h 1h total WIND key To toggle between the followi...

Страница 12: ...the manually set time and date and no further reception is attempted until the following day The manual setting takes the user through the following modes 1 8 level LCD contrast setting default level...

Страница 13: ...Setting Alarms For alarm setting press the ALARM key once while in normal operation mode to enter the normal alarm time and by further pressing the ALARM key will toggle through each of the alarm mode...

Страница 14: ...reach the indoor humidity high alarm set mode 3 Press and hold the SET key to enter the indoor humidity high setting values digits will start flashing and set the desired indoor humidity high by usin...

Страница 15: ...time alarm 2 Continue to press the ALARM key until you reach the rain 1 hour alarm set mode 3 Press and hold the SET key to enter the rain setting values digits will start flashing and set the desire...

Страница 16: ...Alarm BUZZER OFF The time and all the weather alarms may have buzzer sound set to OFF by holding the MINUS key down for about 3 seconds in normal display mode and the BUZZER OFF icon appears on the b...

Страница 17: ...75 2 F with a pre set hysteresis of 1 8 F so that the alarm can be produced again Hysteresis values for the various weather data types are given in the following table For your convenience additional...

Страница 18: ...the low battery indicator will light up on the LCD Please participate in the preservation of the environment by properly disposing of all used up batteries and accumulators at designated disposal poi...

Страница 19: ...n the housing and screen of the base station only with a soft damp cloth Do not use abrasives or solvents Ensure that the rain sensor does not collect leaves or other dirt by checking the funnel for b...

Страница 20: ...of 30 000 ft is around 8 85 inHg Resolution 0 01 inHg Relative humidity checking interval every 30 seconds Alarm duration 2 minutes approx Power consumption Base Station Batteries 3 x AA IEC LR6 1 5V...

Отзывы: