Setting up using the AC adaptor: 

To operate using cable connection, simply use the enclosed 32ft 
cable and connect the thermo-hygro sensor to the base station.  Once 
the connection is detected, the base station will automatically 
continue reading the data from the sensor. 

 
1)  Power up all the sensors as described in setting up using 

batteries above 

2)  Using the AC adaptor (included), plug it into the mains outlet and 

power up the base station by inserting the adaptor jack into the 
DC 6.0V socket located on the side of the base station 

 
The user may at any time switch from cable connection to using 
433MHz (or vice versa) by simply disconnecting (or connecting) the 
cable from the base station to the sensor.  When the base station 
detects no cable connection to the sensors the base station will 
automatically change to using 433 MHz for reception of the weather 
data from the sensors. 

 
Every time the thermo-hygro sensor is powered up (for example after 
a change of batteries), a random security code is transmitted and this 
code must be synchronized with the base station to receive weather 
data. 

The data receiving intervals are as follows: 

  

 -Using cable connection data is updated every 8 seconds. 

When the base station is powered up, a short beep will sound and all 
LCD segments will light up for about 5 seconds before it enters into a 
15 minute learning mode to learn the sensors security code.  After the 
learning mode (or by pressing the MIN/MAX key at anytime), the base 
station will start the WWVB radio controlled time reception. 

 -Using wireless 433 MHz data is updated from 16 to 128 second 
intervals depending on wind speed and rain activity. 
 
Using the AC adaptor to operate the base station will also supply 
power to the sensor if the cable is connected to it.  Batteries used for 
433MHz transmission may be left in the sensor when using cable 
connection for power back up in case of AC power failure.  A loss of 
power would desynchronize the base station and the sensor and no 
weather data will be received.  To Synchronize the units so that the 
weather data can be received, press and hold the PLUS (+) key for 2 
seconds.  However in general, batteries that will not be used for long 
periods should be removed to avoid leakage.   

 

Note for WWVB Radio Controlled Time: 

The time and date display is based on the signal provided by the 
highly accurate government operated atomic clock in Ft. Collins, 
Colorado. This radio-controlled clock does not only provide for the 
weather station’s time and date display but also functions as the time 
and date source for all of this weather station’s memory and history 
values using time and date information. 

 

Wireless 433MHz transmission: 

 

LCD backlight: 

Using 433MHz wireless transmission of weather data from the sensor 
to the base station will provide users greater freedom as to where 
units can be positioned without the need to be restricted by cable. 

When using the power adaptor, the LCD backlight is switched on 
continuously.  Under battery operation, the LCD backlight is switched 
on for 15 seconds intervals when any key is pressed. 

 

Note: 

 

6. 

Operation using cable connection or wireless 433MHz 

If no outdoor weather data is displayed or the signal to the sensors is 
lost during setting up, mounting, changing of batteries to the sensor or 
plugging or unplugging cables, simply press and hold the PLUS (+) 
key for 2 seconds and a short beep will sound to synchronize the 
base station to sensors.  Without being synchronized, weather data 
will not be received. 

 

Cable Connection: 

Using this method of operation will provide interference free transfer 
of the weather data from the sensors to the base station.  The data 
sending interval from the sensors to the base station will also be more 
frequent compared to using 433MHz transmission and will result in 
higher power consumption.  Therefore batteries will have a shorter life 
span for cable connection compared to using 433MHz. 

 

 

 

Содержание WS-2310

Страница 1: ...10 Resetting factory settings 11 Function description 12 Operation keys 13 Basic programming modes 14 MIN MAX programming modes 15 Alarm programming modes 16 Auto memory for stored values 17 Accessor...

Страница 2: ...wind and rain sensors are connected to the thermo hygro sensor for operating power and rely on it to communicate to the base station Weather data sent from the thermo hygro sensor can be done by wire...

Страница 3: ...the data to the base station Operating power is taken from the thermo hygro sensor using a 32ft cable connection Features of Rain sensor The rain sensor measures the rainfall and sends the data to the...

Страница 4: ...hree sockets for the wind sensor rain sensor and the base station 2 Connect the attached cables of wind and rain sensors to the corresponding sockets of the thermo hygro sensor by clicking them into p...

Страница 5: ...ection for power back up in case of AC power failure A loss of power would desynchronize the base station and the sensor and no weather data will be received To Synchronize the units so that the weath...

Страница 6: ...time intervals for the wind readings However the current wind speed or direction will be displayed once the time reading interval is reached For rainfall the interval readings may take up to 2 minute...

Страница 7: ...ignals are received the system can be affixed Also if you have selected to use cable connection ensure that distances can reach all desired locations before affixing any unit permanently Once the wind...

Страница 8: ...gro Sensor However if you wish to make a full reset of the base station and return to the original factory settings simultaneously press and hold the PRESSURE and WIND keys for about 5 seconds The bas...

Страница 9: ...e displayed in different sections on the LCD If this is not the case please observe the notes on Interferences below Sunny Rainy Cloudy Notes to hPa sensitivity setting for weather forecasting The hPa...

Страница 10: ...chill Outdoor dew point Rainfall 24h Rainfall 1h Rainfall total Notes to Dewpoint and Windchill Air can at a certain temperature only carry a certain amount of water water vapor which also increases a...

Страница 11: ...current maximum minimum display modes Indoor temperature and humidity Outdoor temperature and humidity Outdoor wind chill Outdoor dew point Rainfall 24h 1h total WIND key To toggle between the followi...

Страница 12: ...the manually set time and date and no further reception is attempted until the following day The manual setting takes the user through the following modes 1 8 level LCD contrast setting default level...

Страница 13: ...Setting Alarms For alarm setting press the ALARM key once while in normal operation mode to enter the normal alarm time and by further pressing the ALARM key will toggle through each of the alarm mode...

Страница 14: ...reach the indoor humidity high alarm set mode 3 Press and hold the SET key to enter the indoor humidity high setting values digits will start flashing and set the desired indoor humidity high by usin...

Страница 15: ...time alarm 2 Continue to press the ALARM key until you reach the rain 1 hour alarm set mode 3 Press and hold the SET key to enter the rain setting values digits will start flashing and set the desire...

Страница 16: ...Alarm BUZZER OFF The time and all the weather alarms may have buzzer sound set to OFF by holding the MINUS key down for about 3 seconds in normal display mode and the BUZZER OFF icon appears on the b...

Страница 17: ...75 2 F with a pre set hysteresis of 1 8 F so that the alarm can be produced again Hysteresis values for the various weather data types are given in the following table For your convenience additional...

Страница 18: ...the low battery indicator will light up on the LCD Please participate in the preservation of the environment by properly disposing of all used up batteries and accumulators at designated disposal poi...

Страница 19: ...n the housing and screen of the base station only with a soft damp cloth Do not use abrasives or solvents Ensure that the rain sensor does not collect leaves or other dirt by checking the funnel for b...

Страница 20: ...of 30 000 ft is around 8 85 inHg Resolution 0 01 inHg Relative humidity checking interval every 30 seconds Alarm duration 2 minutes approx Power consumption Base Station Batteries 3 x AA IEC LR6 1 5V...

Отзывы: