background image

Poor contrast LCD or 
no reception or low 
batteries in sensors or 
receiver. 

Check the LCD contrast setting or 
change batteries (check low battery 
indicator on the LCD)

 

 
Quite frequently interferences are only of a temporary nature and may 
be easily overcome. If there are wireless headsets, remote 
babysitters or other devices working on 433MHz in your house or in 
the vicinity, their switch-on time is mostly limited. Furthermore most of 
these devices allow the change to an interference-free frequency. 
Such measures will effectively overcome interferences. 

20.  

Transmission Range 

 

The transmission distance from the thermo-hygro sensor to the base 
station in open space under optimum conditions is 100ft.  Although 
the signal transmission may travel though solid surfaces or objects, 
the following points should be avoided if possible: 

 

High frequency interferences of any kind. 

High densities of trees. 

Broadband interferences in municipal areas can reach levels 
reducing the signal/noise ratio over the entire frequency band, 
thus also reducing the transmission distance. 

Devices working close by (example a neighbor’s house) may 
also influence reception. 

Poorly shielded PCs can cause interferences that will reduce or 
in some cases stop reception 

The transmitter and receiver should not be mounted on metal 
surfaces as this will reduce transmission range. 

 
 

21. 

Cleaning and Maintenance 

 

Clean the housing and screen of the base station only with a soft 
damp cloth.  Do not use abrasives or solvents. 

Ensure that the rain sensor does not collect leaves or other dirt 
by checking the funnel for blockages every now and then.  Also 
clean the seesaw of the sensor with a damp cloth and check by 
lightly tapping with your finger that it can move freely from side 
to side. 

- Do 

not

 clean the funnel with the bottom half of the rain sensor 

attached nor the bottom part itself under running water. This 

may bear the danger of water entering the unit’s inner parts and 
cause damages. 

Do not immerse the base station in water. 

Should there be damage to this product, please do not attempt 
to make any repairs.  Please take this unit to a qualified 
technician. Opening or improper handling of the units will 
invalidate any guarantee. 

 

 
 
 
 

22. Specifications 

 

Outdoor data 

Transmission Distance in Open Field: 

100ft max. 

Temperature Range 

-

21.8°F to +157.8°F (show 

OFL” if outside range) 

Resolution : 

0.2°F 

Measuring Range Rel. Humidity 

:  20% to 95% (if the relative 

humidity is less than 20% or 
greater than 95%, it will 
display 19% or 96%)

 

Rain Volume Display 

:  0 to 39.37 inches (1h and 

24h rainfall) 

 

0 to 98.38 inches (Total 
rainfall) 

Resolution : 

0.1mm 

Wind Speed 

:  0 to 111.8 mph 

Resolution : 

0.1 

mph 

Wind Direction 

:  Graphic Resolution 22.5 

Degrees, Numerical 
Resolution, Letter format 

 

Using 433MHz wireless data transmission: 

Measuring interval  
thermo-hygro sensor 

:  32 sec (if wind factor>22.36 

mph) or 128sec (if wind 
factor< 22.36mph) 10 minutes 
(if the base station fails to 
receive any data after 5 
attempts in a row, all outdoor 

Содержание WS-2310

Страница 1: ...10 Resetting factory settings 11 Function description 12 Operation keys 13 Basic programming modes 14 MIN MAX programming modes 15 Alarm programming modes 16 Auto memory for stored values 17 Accessor...

Страница 2: ...wind and rain sensors are connected to the thermo hygro sensor for operating power and rely on it to communicate to the base station Weather data sent from the thermo hygro sensor can be done by wire...

Страница 3: ...the data to the base station Operating power is taken from the thermo hygro sensor using a 32ft cable connection Features of Rain sensor The rain sensor measures the rainfall and sends the data to the...

Страница 4: ...hree sockets for the wind sensor rain sensor and the base station 2 Connect the attached cables of wind and rain sensors to the corresponding sockets of the thermo hygro sensor by clicking them into p...

Страница 5: ...ection for power back up in case of AC power failure A loss of power would desynchronize the base station and the sensor and no weather data will be received To Synchronize the units so that the weath...

Страница 6: ...time intervals for the wind readings However the current wind speed or direction will be displayed once the time reading interval is reached For rainfall the interval readings may take up to 2 minute...

Страница 7: ...ignals are received the system can be affixed Also if you have selected to use cable connection ensure that distances can reach all desired locations before affixing any unit permanently Once the wind...

Страница 8: ...gro Sensor However if you wish to make a full reset of the base station and return to the original factory settings simultaneously press and hold the PRESSURE and WIND keys for about 5 seconds The bas...

Страница 9: ...e displayed in different sections on the LCD If this is not the case please observe the notes on Interferences below Sunny Rainy Cloudy Notes to hPa sensitivity setting for weather forecasting The hPa...

Страница 10: ...chill Outdoor dew point Rainfall 24h Rainfall 1h Rainfall total Notes to Dewpoint and Windchill Air can at a certain temperature only carry a certain amount of water water vapor which also increases a...

Страница 11: ...current maximum minimum display modes Indoor temperature and humidity Outdoor temperature and humidity Outdoor wind chill Outdoor dew point Rainfall 24h 1h total WIND key To toggle between the followi...

Страница 12: ...the manually set time and date and no further reception is attempted until the following day The manual setting takes the user through the following modes 1 8 level LCD contrast setting default level...

Страница 13: ...Setting Alarms For alarm setting press the ALARM key once while in normal operation mode to enter the normal alarm time and by further pressing the ALARM key will toggle through each of the alarm mode...

Страница 14: ...reach the indoor humidity high alarm set mode 3 Press and hold the SET key to enter the indoor humidity high setting values digits will start flashing and set the desired indoor humidity high by usin...

Страница 15: ...time alarm 2 Continue to press the ALARM key until you reach the rain 1 hour alarm set mode 3 Press and hold the SET key to enter the rain setting values digits will start flashing and set the desire...

Страница 16: ...Alarm BUZZER OFF The time and all the weather alarms may have buzzer sound set to OFF by holding the MINUS key down for about 3 seconds in normal display mode and the BUZZER OFF icon appears on the b...

Страница 17: ...75 2 F with a pre set hysteresis of 1 8 F so that the alarm can be produced again Hysteresis values for the various weather data types are given in the following table For your convenience additional...

Страница 18: ...the low battery indicator will light up on the LCD Please participate in the preservation of the environment by properly disposing of all used up batteries and accumulators at designated disposal poi...

Страница 19: ...n the housing and screen of the base station only with a soft damp cloth Do not use abrasives or solvents Ensure that the rain sensor does not collect leaves or other dirt by checking the funnel for b...

Страница 20: ...of 30 000 ft is around 8 85 inHg Resolution 0 01 inHg Relative humidity checking interval every 30 seconds Alarm duration 2 minutes approx Power consumption Base Station Batteries 3 x AA IEC LR6 1 5V...

Отзывы: