Premier Ductable Heaters
www.lbwhite.com
Owner’s Manual • Premier 350
8
8. The hose assembly shall be visually inspected on
a daily basis after heater relocation and when the
heater is in use. If it is evident there is excessive
abrasion or wear, or if the hose is cut, it must be
replaced prior to the heater being put into opera-
tion. The hose assembly shall be protected from
building materials, and contact with hot surfaces
during use. The replacement hose assembly
shall be that speci
fi
ed by the manufacturer. See
parts list.
9. Premier 350DF heaters are equipped with a gas
selector valve. The selector valve must be prop-
erly positioned for the gas supplied to the heater.
Further information on this feature is provided on
page 17 of this manual.
10. Check for gas leaks and proper function upon
heater installation, when relocating, and after
servicing. Refer to leak check instructions within
installation section of this manual.
11. This heater shall be inspected for proper opera-
tion by a quali
fi
ed service person before each
use and at least annually.
12. Always turn off the gas supply to the heater if the
heater is not going to be used in the heating of
the work space.
13. This heater is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and must be plugged directly into
a properly grounded three-prong receptacle.
Failure to use a properly grounded receptacle
can result in electrical shock, personal injury, or
death.
14. If gas
fl
ow is interrupted and
fl
ame goes out, do
not relight the heater until you are sure that all
gas that may have accummulated has cleared
away. In any event, do not relight the heater for
at least 5 minutes.
15. The heater requires a minimum 500 gallon/1892
litre propane tank for proper gas supply pressure
and operation. A larger tank may be required
depending upon operating conditions at the site.
16. When the heater is to be stored indoors, the
connection between the propane gas supply
cylinder(s) and the heater must be disconnected
and the cylinder(s) removed form the heater and
stored in accordance with the Standard for the
Storage and Handling of Liqui
fi
ed Petroleum
Gases, ANSI/NFPA 58 or Standard CSA B149.1
Natural Gas and Propane Installation Code as
appropriate.
17. Propane gas supply containers have left handed
threads. Always use the appropriate wrench
to make a connection to tighten or loosen the
pigtail connector’s P.O.L.
fi
tting at the container’s
gas supply valve.
Содержание Premier 350
Страница 40: ...Premier Ductable Heaters www lbwhite com Owner s Manual Premier 350 40 Service Parts Identification Schematic...
Страница 43: ...Premier Ductable Heaters Owner s Manual Premier 350 43 Notes...
Страница 87: ...Calefactores canalizados Premier Manual del usuario Premier 350 43 Notas...
Страница 131: ...Appareils de chauffage canalisables Premier Guide du propri taire Premier 350 43 Remarques...