Premier Ductable Heaters
www.lbwhite.com
Owner’s Manual • Premier 350
10
-- If a leak is detected, check the components
involved for cleanliness in the thread areas and
proper application of pipe compound before
further tightening.
-- Tighten the gas connection as necessary to stop
the leak.
-- If necessary, replace the parts or components
involved if the leak cannot be stopped.
-- Ensure all gas leaks have been identi
fi
ed and
repaired before proceeding.
7. A quali
fi
ed service agency must check for proper
operating gas pressure upon installation of the
heater.
8. Light according to instructions on heater or within
owner’s manual.
9. Make sure the heater has the proper gas
regulator for the application. A regulator must be
connected to the gas supply so that gas pressure
at the inlet to the gas valve is regulated within the
range speci
fi
ed on the dataplate at all times.
Premier 350DF heaters:
The regulator sup-
plied with the heater is suitable for use with propane
gas or natural gas.
Premier 350 Propane Gas heaters:
The
regulator supplied with these heaters is designed for
use speci
fi
cally for the fuel being used.
Contact your gas supplier, or the L.B. White Co., Inc.
if you have any questions.
10. This heater is con
fi
gured for use for L.P. gas va-
por withdrawal. Do not use the heater in an L.P.
gas liquid withdrawal system or application. If
you are in doubt, contact the L.B. White Co., Inc.
11. The heater must be installed so as not to inter-
fere with or obstruct normal exits, emergency
exits, doors and walkways.
12. Railing, fencing or suitable substitute materials
must be used to keep the heating equipment
from any people using and visiting the structure.
13. The heater shall be located so that rain, ice, or
snow drainage from the structure does not affect
equipment operation. If the heater is mounted
outside, it must be mounted above any pooled or
standing water. If the unit is to be located on
the ground, a surrounding trench is recom-
mended to drain any rain, ice or snow away
from the unit.
14. The ground and surrounding terrain must be
cleared of any combustible vegetation and
other combustible materials when the heater
is utilized outside.
15. Eventually, like all electrical/mechanical
devices, the thermostat can fail. Thermo-
stat failure may result in an underheating
condition. The thermostat should be tested
to make sure it turns the heater on and off
within a temperature differential of ±3°F
(±1.5 °C).
16. Take time to understand how to operate and
maintain the heater by using this Owner’s
Manual. Make sure you know how to shut
off the gas supply to the building and also to
the individual heater. Contact your fuel gas
supplier if you have any questions.
17. Any defects found in performing any of the
service or maintenance procedures must
be eliminated and defective parts replaced
immediately. The heater must be retested by
properly quali
fi
ed service personnel before
placing the heater back into use.
Содержание Premier 350
Страница 40: ...Premier Ductable Heaters www lbwhite com Owner s Manual Premier 350 40 Service Parts Identification Schematic...
Страница 43: ...Premier Ductable Heaters Owner s Manual Premier 350 43 Notes...
Страница 87: ...Calefactores canalizados Premier Manual del usuario Premier 350 43 Notas...
Страница 131: ...Appareils de chauffage canalisables Premier Guide du propri taire Premier 350 43 Remarques...