Flown array options and site angle setting
Flown array options and site angle setting
Using M-BUMP
M-BUMP rigging options
L-Acoustics recommends 5 different rigging options to y the M-BUMP for arrays containing Kara and/or SB18
enclosures. It is possible to use 0, 1, or 2 M-BAR and 1 or 2 rigging points (see gure below).
Always refer to the mechanical data and warning indications provided in
(
Mechanical
Data
section) to verify the mechanical conformity of the loudspeaker system before installation.
Option 1: 0 M-BAR, 1 point
1 motor
3 positions (front, center, rear)
Option 2: 0 M-BAR, 2 points
2 motors
Fixed front and rear positions
(spacing = 400 mm/15 inch)
Option 3: 1 M-BAR, 1 point
(p.190))
Left view = rear extension conguration
Right view = front extension conguration
Option 4: 1 M-BAR, 2 points
2 motors
Fixed front and rear positions
(spacing = 900 mm/35 inch)
Left view = rear extension conguration
Right view = front extension conguration
Option 5: 2 M-BAR, 2 points
2 motors
Variable position from front to rear
Same hole number for both points [8.2.2]
(spacing = 663 mm/26 inch)
Left view = rear extension conguration
Right view = front extension conguration
Kara owner's manual (EN) version 1.0
189
Содержание LA-RAK
Страница 1: ...Kara owner s manual EN ...
Страница 5: ...APPENDIX D Safety pin removal and insertion 199 APPENDIX E Recommendation for speaker cables 200 5 ...
Страница 148: ...Corrective maintenance 5 Secure the handle 5 mm 5 N m 148 Kara owner s manual EN version 1 0 ...
Страница 179: ...Speci cations SB18 dimensions 750 mm 29 5 in 707 mm 27 8 in 553 mm 21 8 in Kara owner s manual EN version 1 0 179 ...
Страница 181: ...Speci cations SB28 dimensions 700 mm 27 6 in 1300 mm 51 2 in 550 mm 21 7 in Kara owner s manual EN version 1 0 181 ...
Страница 201: ...L Acoustics 13 rue Levacher Cintrat 91460 Marcoussis France 33 1 69 63 69 63 info l acoustics com www l acoustics com ...