Rigging procedures
7.
(p.117) until all SB18 enclosures composing the array are rigged.
Orient all SB18 composing the array towards the audience to obtain an omnidirectional acoustic pattern
or turn one SB18 out of four from front to rear to obtain a cardioid acoustic pattern (refer to the
). As an example, the following gures show a cardioid SB18 array.
8.
If the array is intended to be an SB18 standalone array, apply the following last procedure:
a) Check if the stacking platform is still horizontal. If not, refer to step
(p.91) from the
Array mounting
procedure in
Stacking a Kara standalone array using M-BUMP
.
b) Secure the system to a xed point using a ratchet strap or any other applicable material (not provided).
If the array is intended to be an SB18/Kara mixed array, place a second M-BUMP at the rigging location. Turn it so that
the text of the identication plate is upside down and the laser slits are directed towards the audience, and place it on
the top SB18.
For clarity purposes, the procedure is continued with an array composed of one SB18 enclosure.
118
Kara owner's manual (EN) version 1.0
Содержание LA-RAK
Страница 1: ...Kara owner s manual EN ...
Страница 5: ...APPENDIX D Safety pin removal and insertion 199 APPENDIX E Recommendation for speaker cables 200 5 ...
Страница 148: ...Corrective maintenance 5 Secure the handle 5 mm 5 N m 148 Kara owner s manual EN version 1 0 ...
Страница 179: ...Speci cations SB18 dimensions 750 mm 29 5 in 707 mm 27 8 in 553 mm 21 8 in Kara owner s manual EN version 1 0 179 ...
Страница 181: ...Speci cations SB28 dimensions 700 mm 27 6 in 1300 mm 51 2 in 550 mm 21 7 in Kara owner s manual EN version 1 0 181 ...
Страница 201: ...L Acoustics 13 rue Levacher Cintrat 91460 Marcoussis France 33 1 69 63 69 63 info l acoustics com www l acoustics com ...