Inclinometer mounting
Sensor mounting procedure
Required tools
• handheld inclinometer (available in the
TECH TOOLCASE
)
• electric screwdriver with torque selector
• T20 Torx bit
• 7 mm hex key
• XLR cable
Procedure
1.
Place the M-BUMP / KARA-MINIBU on a at horizontal surface (use the handheld inclinometer).
2.
Unscrew the four Torx bolts from the laser support plate (T20 bit, 7 mm hex key).
3.
Mount the sensor on the laser support plate with laser lens towards the M-BUMP / KARA-MINIBU slits.
4.
Screw the 4 Torx bolts to the sensor and plate (T20 bit, 7 mm hex key, 3 N.m / 27 in.lb
f
).
5.
Connect an XLR cable to the sensor.
6.
Calibrate the sensor by following the manufacturer’s recommendations.