50
The second stage then reduces the 10-13 pound pressure to an operating
pressure of 11 inches W.C. (water column) or 6.35 ounces of outlet
pressure to your appliances. The second stage is adjustable and may
need to be adjusted for precise operation. We suggest this to be normal
maintenance and performed once per year.
DO NOT
make this
adjustment without a manometer. This instrument is required to read
actual pressure.
If pressure is too high, it affects performance and safety. Should pressure
be too low, appliances will not operate correctly. An authorized technician
with proper equipment should perform such tests and adjustments, as
may be required.
Your propane regulator that is used on Classic and Escape products is
the standard two stage regulator. This standard regulator is used on
smaller coaches.
After filling the cylinder, connect the pigtail hose and slowly open the
bottle valve.
Do not
forget to check for leakage each time you refill
cylinder or disconnect any part on the propane system.
High Pressure Hoses with ACME Connectors
Propane leaves the container through a hose with an ACME connector
attached to the bottle, also having a “flow-limiting device”. Should the
container valve be opened too quickly, this device may close, stopping
the flow of propane. Should there be a rupture or break in the propane
line, it will reduce the flow to a maximum of (SCFH) Standard Cubic Feet
per Hour.
Main Supply Hose
– Low Pressure
The main supply hose will be attached to the regulator and manifold fitting
attached to front cross member of frame.
The swivel brass nut on the main hose will be your final attachment.
There are several things to remember each time the container is
removed:
1. Be sure ALL fittings are tight. Always use two open end or 6
point wrenches for brass connections.
2. Be sure ALL connections are tested for leakage.
3/8” MPT x 1/2”
Female Flare Swivel
Содержание Escape 2020
Страница 71: ...71...