61
Your basic operation is performed through a thermostat to operate
furnace.
The thermostat as shown here is installed into coaches
which DO NOT have central air conditioning. There is an
“ON/OFF” switch on the left upper corner.
Operating Instructions
1. Before operating your furnace, read and be
familiar with all safety and warning information supplied by the
manufacturer of the furnace.
2. Allow 5 minutes of time with windows and door to be open,
allowing full ventilation should any propane odors remain inside.
3. Be sure your propane container valve is turned open and 12-
Volt DC power is available. A switch is on the side of the furnace,
which must be turned “ON”. If blower runs, switch is in “ON”
position.
4. Slide thermostat lever from
“OFF” position to 60 degrees.
5. Blower will come on in 15 seconds and run about 30 seconds to
purge heat chamber.
6. Module board has 3 functions: (1) Send spark to burner tube.
(2) Open propane v
alve. (3) Send signal to board “burner is lit”,
stop sparking. Board will lockout after trying 3 times to light.
After lockout, shut thermostat down, wait 2 minutes and repeat
operation.
7. When burner ignites, board will discontinue to spark. You should
feel heat within 1 minute at the ducts.
8. Set your thermostat at desired temperature.
9. To shut-down, move thermostat lever to far left and power will
cease to flow to furnace. Blower will continue to run about 2
minutes until heat has left chamber.
Be sure to follow all directions to operate furnace and to
prevent any damages or malfunctions. Errors could cause
personal injury.
Do not install screens over the vents for any reason. Screens
will become restricted causing unsafe or inefficient operation.
DO NOT operate furnace while vehicle is in motion or being
towed.