![KZ Escape 2020 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/kz/escape-2020/escape-2020_owners-manual_2018116028.webp)
28
Simultaneous CO and Gas Alarms
Because the risk of a propane gas explosion is generally a more serious
danger, your alarm unit gives the gas alarm a higher priority during
simultaneous alarm condition.
If your unit generates alarms for both Gas and CO at the same time, the
gas LED will flash red and the beeper will sound. The CO LED will be a
solid Red until the CO is ventilated out of the RV, at which time the LED
will return to the Green operational/safe color.
Brownout Protection
The unit can tolerate short power interruptions and brownouts where the
circuit voltage drops as low as 1 VDC. If the brownout lasts too long, the
unit will reset and operate as described previously.
Low Power Operating Instructions
This alarm will operate normally down to 7 VDC. Below 7 VDC your alarm
will not function.
Visual and Audible Alarm Signals
This SAFE-T-
ALERT™ CO/Propane Gas Alarm is designed to be easy-
to-operate. The alarm has two indicator lights that display a specific color
for each monitored condition. There also is a matching sound pattern for
alarm conditions.
CO Alarm
The Red CO LED will flash and the alarm will sound 4 “BEEPS” then silent
for 5 seconds. These signals indicates that the CO level is over 35 ppm.
IMMEDIATE ACTION IS REQUIRED.
See
Procedures To Take During
An Alarm.
This cycle will continue until the TEST/Mute button on the front
of alarm is pressed. Ventilate the RV. The RED light will stay ON until the
CO has cleared, or the alarm will reactivate in approximately 6 minutes if
the CO is still present.
DO NOT
RE-ENTER THE RV. This alarm will
return to normal operation after the RV is properly ventilated.
Propane Gas Alarm
The RED LED will flash and the alarm will sound a steady tone whenever
a dangerous level of propane or butane gas is detected.
IMMEDIATE
ACTION IS REQUIRED.
See
Procedures To Take During A Gas
Alarm.
The detector will continue to alarm until the Test/Mute switch on
the front of the alarm is pressed. Ventilate the RV. The RED Gas LED will
continue to flash until the gas has cleared, or the gas alarm will reactivate
in approximately 5 minutes if the gas is still present.
DO NOT
RE-ENTER
THE RV. This alarm will return to normal operation after the RV is properly
ventilated.
Malfunction/Service Signal
If any malfunction is detected, the Gas LED will remain off and the
Operational/CO LED will alternate Red/Green and the alarm will sound
Содержание Escape 2020