Receiving/Shipping Damage/Lost Items
All equipment should be examined for shipping damage before and during unloading. If there is
any damage, the carrier should be notified immediately and an inspection requested. The
delivery receipt must be noted that the equipment was received damaged. If damage is of a
concealed nature, you must contact the carrier within three (3) days following delivery. The
consignee for all damages must file a claim with the carrier.
NOTE:
All claims for shortages must be within 10 days after receipt of shipment.
Refrigerant
A variety of refrigerants can be used in the Kysor//Warren cases provided the correct expansion
valve is equipped with the case when ordered (i.e., R404A required for the end user requires
specifying the correct expansion valve for R404A refrigerant when the order is placed). Multiple
expansion valves are available, depending on end user refrigerant requirements. Expansion
valves are supplied for the refrigerant specified on the original sales order.
In addition, cases can be modified in the field to allow changing the type of refrigerant used.
This requires changing the expansion valve and distributor orifice that is currently equipped in
the case. Contact your Kysor//Warren Service Representative for additional information.
NOTE:
Refer to Case Data Control Settings for refrigeration requirements.
Heat Exchangers
Heat exchangers are standard in some models, optional in other models, and are not needed if
mechanical sub-cooling is incorporated in the system design. They are an aid to increasing
operating efficiency and reducing frosting and flood-back to the compressor.
7
Содержание 6RLG3
Страница 3: ...2 6 2006 2 Addendum Ballast Relocation 2 ...
Страница 5: ...2 6 2006 4 Addendum Ballast Relocation Wiring Diagram Both Canopy and Raceway 4 ...
Страница 6: ...2 6 2006 5 Addendum Ballast Relocation Wiring Diagram for Canopy Light 5 ...
Страница 9: ...Plan Views and Cross Sections D6L D6 D6H 8 ...
Страница 10: ...D6RL D6R 9 ...
Страница 11: ...QD6 10 ...
Страница 12: ...HQD6 8 11 16 44 1 16 39 11 16 4 23 5 8 6 80 9 16 43 1 8 32 1 16 59 13 16 50 1 16 22 15 5 8 L OAD LIMIT 11 ...
Страница 34: ...D6 Electrical Model Table QD6 1 3 04 Through D6H 1 3 6 UNIT INSTALLATION 33 ...
Страница 35: ...D6 Electrical Model Table D6H 1 3 6 Through D6R 1 3 4 UNIT INSTALLATION 34 ...
Страница 36: ...D6 Electrical Model Table D6R 1 3 4 Through D6RL G 1 6 UNIT INSTALLATION 35 ...
Страница 39: ...Wiring Diagram UNIT INSTALLATION 38 ...
Страница 40: ...Wiring Diagram Canopy One 1 and Two 2 Light Rows UNIT INSTALLATION 39 ...
Страница 41: ...Wiring Diagram Canopy Two 2 and Three 3 Light Rows UNIT INSTALLATION 40 ...
Страница 42: ...Wiring Diagram Canopy Two 2 Light Rows and Nose Light UNIT INSTALLATION 41 ...
Страница 43: ...Wiring Diagram Off Cycle Defrost UNIT INSTALLATION 42 ...