Introductions – General Information
This manual has been prepared for our customers and the personnel involved in setting up and
maintaining our cases.
The Kysor//Warren multi-shelf self service dairy cases are designed to merchandise packaged
dairy/deli products.
These cases should be installed and operated according to the instructions contained in this
manual to insure proper performance. They are designed for display of products in an air-
conditioned store where temperature and humidity are maintained at a maximum of 75º dry-bulb
temperatures and 55% relative humidity.
CAUTION: Failure to maintain maximum design
conditions may result in operational issues such as: increased
BTUH load, high product temperature, coil icing, product
frosting, and external sweating.
Case Description
Model
Description
HQD6
High energy efficient front load dairy case.
HQD6L
High energy efficient front load dairy case.
D6L(1)(3)
Front load dairy case, Front height 19.5", Standard (4) adjustable shelves 20",
22"
*(Q)D6(1)(3)
Front load dairy case, Front height 23.75", Standard (4) adjustable shelves 20",
22", 24"
*(Q)D6H(1)(3)
Front load dairy case, Front height 28.25", Standard (4) adjustable shelves 20",
22", 24"
**D6R(1)(3)
Rear load dairy case, Front height 23.75", Standard (4) adjustable shelves 20",
22"
**D6RL(1)(3)
Rear load dairy case, Front height 19.5", Standard (4) adjustable shelves 20",
22"
**D6RLG(1)(3)
Rear load dairy case with glass front, Front height 19.5" plus glass height,
Standard (4) adjustable shelves 20", 22"
**D6N(1)(3)
Front load dairy case, Front height 38.25", Standard (5) adjustable shelves 10",
12", 14", 16", 18"
* These models may be used for deli (processed meats) with proper BTU capacity and
Kysor//Warren special hook-a-pack systems are used or 18" and 20" shelves are used above a hook-
a-pack system supplied by others.
** All rear load dairy cases must be installed in a wall of a walk-in cooler where the ambient
temperature is less than 40° F. These cases are not intended to operate as free standing models.
Icon Key
Caution
Special Note
Warning
6
Содержание 6RLG3
Страница 3: ...2 6 2006 2 Addendum Ballast Relocation 2 ...
Страница 5: ...2 6 2006 4 Addendum Ballast Relocation Wiring Diagram Both Canopy and Raceway 4 ...
Страница 6: ...2 6 2006 5 Addendum Ballast Relocation Wiring Diagram for Canopy Light 5 ...
Страница 9: ...Plan Views and Cross Sections D6L D6 D6H 8 ...
Страница 10: ...D6RL D6R 9 ...
Страница 11: ...QD6 10 ...
Страница 12: ...HQD6 8 11 16 44 1 16 39 11 16 4 23 5 8 6 80 9 16 43 1 8 32 1 16 59 13 16 50 1 16 22 15 5 8 L OAD LIMIT 11 ...
Страница 34: ...D6 Electrical Model Table QD6 1 3 04 Through D6H 1 3 6 UNIT INSTALLATION 33 ...
Страница 35: ...D6 Electrical Model Table D6H 1 3 6 Through D6R 1 3 4 UNIT INSTALLATION 34 ...
Страница 36: ...D6 Electrical Model Table D6R 1 3 4 Through D6RL G 1 6 UNIT INSTALLATION 35 ...
Страница 39: ...Wiring Diagram UNIT INSTALLATION 38 ...
Страница 40: ...Wiring Diagram Canopy One 1 and Two 2 Light Rows UNIT INSTALLATION 39 ...
Страница 41: ...Wiring Diagram Canopy Two 2 and Three 3 Light Rows UNIT INSTALLATION 40 ...
Страница 42: ...Wiring Diagram Canopy Two 2 Light Rows and Nose Light UNIT INSTALLATION 41 ...
Страница 43: ...Wiring Diagram Off Cycle Defrost UNIT INSTALLATION 42 ...