UNIT INSTALLATION
These display cases may be installed individually or in a continuous line up consisting of several
4’, 6’, 8’ and 12’ sections using a joint kit. A Plexiglas divider kit must be used between cases
operating on different refrigeration systems. The divider will be factory installed if specified on
order.
Shipping
Damage
All equipment should be examined for shipping damage before and during unloading. If there is
any damage, the carrier should be notified immediately and an inspection requested. The
delivery receipt must be noted that the equipment was received damaged. If damage is of a
concealed nature, you must contact the carrier within three (3) days following delivery. A claim
must be filed with the carrier by the consignee for all damages.
Note:
All claims for shortages must be within 10 days after receipt of shipment.
Installation
Location and Preparation
Proper installation of the case ensures maximum case life and ensures all future warranty claims,
if required, will be honored. Review the following instructions and contact your Kysor//Warren
Service Representative if there are any questions or concerns.
Location
and
Special Precautions
Caution:
Influences, such as heating and air conditioning outlets and outside
entrances, may adversely affect the operation of the case. Damage to case contents may
occur if case temperature is not properly maintained. Follow all recommendations for
case installation.
Caution:
To prevent condensation on the end panels of cases, a minimum of 6.0
inches between walls or other units is required for air flow. If 6.0 inches is not
possible, then the space between the units must be completely filled and sealed or an
updraft fan kit must be installed to provide air circulation through the space.
Caution:
The installation area must be clean of all debris that may restrict airflow or
otherwise inhibit proper installation. In addition, it is recommended that all
refrigeration units are located at least 15 feet away from outside entrance doorways or
heating and air conditioning outlets that may adversely affect case temperature.
19
Содержание 6RLG3
Страница 3: ...2 6 2006 2 Addendum Ballast Relocation 2 ...
Страница 5: ...2 6 2006 4 Addendum Ballast Relocation Wiring Diagram Both Canopy and Raceway 4 ...
Страница 6: ...2 6 2006 5 Addendum Ballast Relocation Wiring Diagram for Canopy Light 5 ...
Страница 9: ...Plan Views and Cross Sections D6L D6 D6H 8 ...
Страница 10: ...D6RL D6R 9 ...
Страница 11: ...QD6 10 ...
Страница 12: ...HQD6 8 11 16 44 1 16 39 11 16 4 23 5 8 6 80 9 16 43 1 8 32 1 16 59 13 16 50 1 16 22 15 5 8 L OAD LIMIT 11 ...
Страница 34: ...D6 Electrical Model Table QD6 1 3 04 Through D6H 1 3 6 UNIT INSTALLATION 33 ...
Страница 35: ...D6 Electrical Model Table D6H 1 3 6 Through D6R 1 3 4 UNIT INSTALLATION 34 ...
Страница 36: ...D6 Electrical Model Table D6R 1 3 4 Through D6RL G 1 6 UNIT INSTALLATION 35 ...
Страница 39: ...Wiring Diagram UNIT INSTALLATION 38 ...
Страница 40: ...Wiring Diagram Canopy One 1 and Two 2 Light Rows UNIT INSTALLATION 39 ...
Страница 41: ...Wiring Diagram Canopy Two 2 and Three 3 Light Rows UNIT INSTALLATION 40 ...
Страница 42: ...Wiring Diagram Canopy Two 2 Light Rows and Nose Light UNIT INSTALLATION 41 ...
Страница 43: ...Wiring Diagram Off Cycle Defrost UNIT INSTALLATION 42 ...