INSPECTION
This Inspection chapter provides the instructions to follow whenever maintenance is performed
on the case.
Leakage
Inspect components (evaporator coil, expansion valve, filters, etc.), for any signs of leakage.
Leakage can be identified by excessive build up of oil around the area that is leaking. If leakage
is found, either tighten applicable fittings or remove and replace the components using the
documentation for that compressor.
Lights
Ensure all lights are functioning. If lights are not functioning, troubleshoot system and remove
and replace the applicable components using the instructions provided in the applicable chapters
of this manual.
Shelf
Alignment
Ensure all shelves are properly aligned and are at the same height. If a shelf is not aligned
properly, remove the shelf, make the necessary adjustment to the shelf support, and then
re-install the shelf.
Fans
Ensure all fan(s) are functioning properly. If fan(s) are not functioning, troubleshoot system per
the Troubleshooting chapter of this manual.
Refrigerant
Lines
Inspect refrigerant lines for any signs of leakage. Leakage can be identified by excessive build
up of oil around the area that is leaking. If leakage is found, either tighten applicable fittings or
remove and replace the defective refrigerant lines using the instructions provided in the
applicable chapters of this manual.
Case
Temperature
Inspect to ensure case temperature is properly maintained and that the case contents also
maintain the proper temperature. Refer to the Operation chapter of this manual.
68
Содержание 6RLG3
Страница 3: ...2 6 2006 2 Addendum Ballast Relocation 2 ...
Страница 5: ...2 6 2006 4 Addendum Ballast Relocation Wiring Diagram Both Canopy and Raceway 4 ...
Страница 6: ...2 6 2006 5 Addendum Ballast Relocation Wiring Diagram for Canopy Light 5 ...
Страница 9: ...Plan Views and Cross Sections D6L D6 D6H 8 ...
Страница 10: ...D6RL D6R 9 ...
Страница 11: ...QD6 10 ...
Страница 12: ...HQD6 8 11 16 44 1 16 39 11 16 4 23 5 8 6 80 9 16 43 1 8 32 1 16 59 13 16 50 1 16 22 15 5 8 L OAD LIMIT 11 ...
Страница 34: ...D6 Electrical Model Table QD6 1 3 04 Through D6H 1 3 6 UNIT INSTALLATION 33 ...
Страница 35: ...D6 Electrical Model Table D6H 1 3 6 Through D6R 1 3 4 UNIT INSTALLATION 34 ...
Страница 36: ...D6 Electrical Model Table D6R 1 3 4 Through D6RL G 1 6 UNIT INSTALLATION 35 ...
Страница 39: ...Wiring Diagram UNIT INSTALLATION 38 ...
Страница 40: ...Wiring Diagram Canopy One 1 and Two 2 Light Rows UNIT INSTALLATION 39 ...
Страница 41: ...Wiring Diagram Canopy Two 2 and Three 3 Light Rows UNIT INSTALLATION 40 ...
Страница 42: ...Wiring Diagram Canopy Two 2 Light Rows and Nose Light UNIT INSTALLATION 41 ...
Страница 43: ...Wiring Diagram Off Cycle Defrost UNIT INSTALLATION 42 ...