3LL/3LK-3
1-4-2
Fullcolor machine
Section
Jam code
Conditions
Specified time
25/25 ppm
30/30 ppm
40/40 ppm
50/40 ppm
55/50 ppm
DP
70
No original feed
The original feed switch (OFSW) does not turn on within
specified time during the first sheet feeding (Retry 5
times).
1159 ms
705 ms
The original feed switch (OFSW) does not turn on within
specified time during the second sheet feeding (Retry 5
times).
1159 ms
705 ms
During original tray ascent, the tray upper limit switch
(TULSW) does not turn on within specified time.
2 s
2 s
71
An original jam in
the original feed sec-
tion
The original registration switch (ORSW) does not turn on
within specified time of the original feed switch (OFSW)
turning on.
914 ms
557 ms
72
An original jam in
the original convey-
ing section
DP timing switch 1 (DPTSW1) turns off within the speci-
fied time since the switch turns on.
914 ms
557 ms
73
An original jam in
the original registra-
tion section
During single scanning, the DP timing switch 1
(DPTSW1) does not turn on within specified time of the
original registration switch (ORSW) turning on (Retry 5
times).
1774 ms
1080 ms
During duplex switchback scanning, the DP timing
switch 1 (DPTSW1) does not turn on within specified
time of the original registration switch (ORSW) turning
on (Retry 5 times).
1774 ms
1080 ms
During dual scanning, the DP timing switch 2 (DPTSW2)
does not turn on within specified time of the original reg-
istration switch (ORSW) turning on (Retry 5 times).
1014 ms
617 ms
74
An original jam in
the original feed sec-
tion
The original feed switch (OFSW) or original registration
switch (ORSW) does not turn off within specified time of
the DP timing switch 1 (DPTSW1) turning on.
2084 ms
1268 ms
Scanning of previous original is not complete when DP
timing switch 1 (DPTSW1) turns on.
-
-
75
An original jam in
the original convey-
ing section
During single scanning, the DP timing switch 1
(DPTSW1) does not turn off within specified time of the
original registration switch (ORSW) turning off.
1416 ms
862 ms
During duplex switchback scanning, the DP timing
switch 1 (DPTSW1) does not turn off within specified
time of the original registration switch (ORSW) turning
off.
1416 ms
862 ms
During dual scanning, the DP timing switch 2 (DPTSW2)
does not turn off within specified time of the original reg-
istration switch (ORSW) turning off.
656 ms
400 ms
76
An original jam in
the original switch-
back section 1
During duplex switchback scanning, the switchback tray
switch (SBTSW) does not turn on within specified time of
the DP timing switch 1 (DPTSW1) turning on.
2318 ms
1411 ms
Содержание DP-750
Страница 1: ...SERVICE MANUAL Published in November 2009 843LL113 3LLSM063 Rev 3 DP 750 DP 750 B DP 760 DP 760 B ...
Страница 4: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 16: ...3LL 3LK 1 1 4 This page is intentionally left blank ...
Страница 20: ...3LL 3LK 1 2 4 This page is intentionally left blank ...
Страница 78: ...3LL 3LK 1 4 12 This page is intentionally left blank ...
Страница 94: ...3LL 3LK 1 6 2 This page is intentionally left blank ...
Страница 102: ...3LL 3LK 2 1 8 This page is intentionally left blank ...
Страница 120: ...3LL 3LK 2 4 4 This page is intentionally left blank ...
Страница 123: ......
Страница 124: ......