3LL/3LK-2
1-3-34
U203
Operating the DP separately
Description
Simulates the original conveying operation separately in the DP.
Purpose
To check the DP operation.
Method
1. Press the start key.
2. Place an original in the DP if running this simulation with paper.
3. Select the item to be operated.
*: Dual scan DP only.
4. Press the start key. The operation starts.
5. To stop continuous operation, press the stop key.
Completion
Press the stop key when the operation stops. The screen for selecting a maintenance item No. is displayed.
U243
Checking the operation of the DP motors
Description
Turns the motors or solenoids in the DP on.
Purpose
To check the operation of the DP motors and solenoids.
Method
1. Press the start key.
2. Select the item to be operated.
3. Press the start key. The operation starts.
*: Dual scan DP only.
4. To turn each motor off, press the stop key.
Completion
Press the stop key when operation stops. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Display
Description
Setting range
Initial setting
CCD ADP
(NON P)
Without paper, single-sided original of CCD
(continuous operation)
-
-
CCD ADP
With paper, single-sided original of CCD
-
-
CCD RADP
(NON P)
Without paper, double-sided original of CCD
(continuous operation)
-
-
CCD RADP
With paper, double-sided original of CCD
-
-
CIS RADP
(NON P)*
Without paper, double-sided original of CIS
(continuous operation)
-
-
CIS RADP*
With paper, double-sided original of CIS
-
-
SPEED
Switching between normal reading (600 dpi)
and high-speed reading
0 (Normal)/
1 (High-speed)
0
Display
Motor and solenoid
Operation
DP FEED MOT
Original feed motor (OFM)
In operation
DP CON MOT
Original conveying motor (OCM)
In operation
DP REV MOT
Original switchback motor (OSBM)
In operation
DP LIFT MOT
DP lift motor (DPLM)
In operation
DP REV PRS SOL
Switchback pressure solenoid (SBPSOL)
On for 0.5 s
DP REV BRCH SOL
Switchback feedshift solenoid (SBFSSOL)
On for 0.5 s
CIS FAN*
DP fan motor (DPFM)
In operation
Содержание DP-750
Страница 1: ...SERVICE MANUAL Published in November 2009 843LL113 3LLSM063 Rev 3 DP 750 DP 750 B DP 760 DP 760 B ...
Страница 4: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 16: ...3LL 3LK 1 1 4 This page is intentionally left blank ...
Страница 20: ...3LL 3LK 1 2 4 This page is intentionally left blank ...
Страница 78: ...3LL 3LK 1 4 12 This page is intentionally left blank ...
Страница 94: ...3LL 3LK 1 6 2 This page is intentionally left blank ...
Страница 102: ...3LL 3LK 2 1 8 This page is intentionally left blank ...
Страница 120: ...3LL 3LK 2 4 4 This page is intentionally left blank ...
Страница 123: ......
Страница 124: ......