This document is the property of KYMATI GmbH and must not be copied or disclosed without its written authorisation.
- KYMATI GmbH – 2021
KY.MAN.0105 (6.0)
KY-LOC 1D.02.01 User Manual
Doc.- No.: KY.MAN.0105
Version:
6.0
Date:
14.12.2021
Page:
48 of 83
Figure 33: Sensor Wizard ‘Double Crane’ application
After choosing the anticollision mode and application type, the user should input a
collection of values to successfully setup the anticollision feature. These values are
chosen based on the user’s preference and few values are based on the vehicle on
which the sensor(s) is mounted. These are all the values that might be required from
the user to input:
Fixed Warning Zones:
o
MA1/MA2 [m]: two different warning zones for side A of Master sensor
o
MB1/MB2 [m]: two different warning zones for side B of Master sensor
o
SA1/SA2 [m]: two different warning zones for side A of Slave sensor
o
ML [m]: total distance of the operational area of the sensors.