X1 Connector
Function
Pin 1
RS-485-P
Pin 2
RS-485-N
Pin 3
DC In (9 - 36V DC)
Pin 4
GND
Pin 5
N.A.
Table 2: Pin Definition X1 (DC/RS-485 connector)
The DC/RS-485 connector provides a half-duplex serial RS-485 Interface. Further details on
the RS-485 are mentioned in chapter 0.
There is no termination of the RS-485 interface included in the device, so the
bus must be terminated externally.
The IP rating of the unit is only ensured if a connector cap (default) or a
connector is mounted correctly.
X2: Ethernet connector:
Connector type: M12 according to IEC
61076-2 -101, 102 & 109
, 8 pin, female, X-coding,
material: Zinc Die Cast (default) or 1404 Steel (on customer request) Further details on the
Ethernet interface are mentioned in chapter 0.
Figure 13: Connector X2 pin diagram (front view of male connector with pin numbers)
X2 Connector
Function
Pin 1
TX+
Pin 2
TX-
Pin 3
RX+
Pin 4
RX-
Pin 5
DC-
Pin 6
DC-
Pin 7
DC+
Pin 8
DC+
Table 3: Pin Definition X2 (Ethernet Connector)
The IP rating of the unit is only ensured if a connector cap (default) or a
connector is mounted correctly.
4.6
Indicators
For the detailed description of the following LEDs and the corresponding blinking patterns,
please refer to the Troubleshooting section of this manual (Chapter 11).