This document is the property of KYMATI GmbH and must not be copied or disclosed without its written authorisation.
- KYMATI GmbH – 2021
KY.MAN.0105 (6.0)
KY-LOC 1D.02.01 User Manual
Doc.- No.: KY.MAN.0105
Version:
6.0
Date:
14.12.2021
Page:
31 of 83
Figure 16: Typical Set-up
After mounting the device, the cable(s) must be connected. It is preferable to use the master
device on the moving side and the slave on the fixed/stationary side. Please attach in minimum
the power to both devices and at least communication to one of the devices where the distance
measurements are needed.
Do not use unintended force to mount the connectors. If the connector does
not fit, check the coding/index notch of the connector.
Open connector sockets need to be protected with a cap. Only with sealed
connectors, the device has its stated IP rating.
6.2
Powering Up
First connect all cables to the devices and then power up them.
After the installation of the devices the power can be turned on. Therefore, a proper power
supply as described in chapter 4.4 must be used.
After power up, the power LED shall illuminate constantly, stating that the device is properly
powered. In case of wrong polarity, the device has a polarity protection, hence if the power
LED is not illuminating, the power must be removed immediately.
6.3
Initial Configuration
The devices must be configured during initial setup and the parameters must be configured
through the commissioning tool provided by KYMATI. To configure the device the Ethernet
interface shall be used. How to connect to the device is described above.