Programming the KYK Alkaline Water Ionizer
❾
Touching the
Mode
touch sensor ONCE.
❿
“
Clean
”
will start flashing on the LCD display.
This sets how often the automatic cleaning operates. Leave as programmed. Continue by:
Touching the
Mode
touch sensor ONCE.
“
Alkali
”
and
“
pH
”
will be flashing. This allows you to increase or decrease the alkalinity of the
four present alkaline water levels. The present values are: pH 8.5 (step one), pH 9.0 (step two), pH
9.5 (step three) and pH 10.0 (step four). This step is not necessary, but it will optimize pH for the
alkaline water delivered at the stainless steel output hose. This step will also optimize the acidity of
the water delivered at the lower output (drain) line. If your product is installed such that the drain line
empties into your sink (not connected directly to a permanent drain, you can bottle acidic water
(from the lower drain line) while you are making alkaline water delivered at the upper stainless steel
hose. If you want to do this programming, read the following paragraph. If you want to skip this step,
continue by touching the
Mode
touch sensor ONCE.
To do this programming, increase the value shown on the display to the maximum number. Then
touch the Alkali touch sensor once. This sets the first alkaline level. Once again, increase the value
shown on the display to the maximum and touch the
“
Alkali
”
touch sensor once. This sets the
second alkaline level. Increase the value on shown on the display to the maximum number and touch
the
“
Alkali
”
touch sensor once. This sets the third alkaline level. Increase the value shown on the
display to the maximum number and touch the
“
Alkali
”
touch sensor. This sets the fourth alkaline
level. Continue by:
Touching the
Mode
touch sensor ONCE.
“
Alkal
”
and
“
ORP
”
will be flashing. This allows you to increase or decrease the ORP value of
the four alkaline preset alkaline water levels. A higher ORP setting will give the water more
antioxidant capabilities (more ability to counter free radical activity in the body). It is recommended
that you do this. Hold the
“
+
”
touch sensor down to obtain the highest negative ORP value and then
touch the
“
Alkal
”
touch sensor once to select the first maximum ORP value. Hold the
“
+
”
touch
sensor down again to obtain the highest negative ORP value and then touch the
“
Alkal
”
touch
sensor once to select the second maximum ORP value. Repeat this procedure for the third and
fourth levels.
You are done programming your product. Touch the
“
SET
”
touch sensor to exit product
Programming.
Installation Cautions
Your Product must be connected ONLY to a 110 Volt or 220 Volt power source.
Higher voltage supply will damage the unit. so before connecting the electricity code,
you must check the voltage.
Do not install the product at the area which exposes directly to the sun and
below zero. (There is a danger of distortion and frost wedging of product.)
Do not install the product in an area of direct and constant sunlight anddirector heat
(a furnace vent for example).
Connect the product ONLY to the cold water supply Make sure the faucet is turned to
the cold water position. Hot water will damage the unit
The acidic water draining hose is placed lower than the body. If the length of hose is
longer or higher than the body, it will affect the ionization and be possible to change
a taste of water.
※
After installation, do not turn and bush the acidic water hose.
Do not alter the product intentionally. This could result in failure of the unit and
danger to the user.
Check your input and
output hoses for kinks.
Check to make sure that
none of the supply or
drain tubing is kinked.
Do not install the product
on the inclination and
keep the body on the
horizontal plane.
Install the product on a
level surface.
Install the product on a
higher place than a tap
for water draining.
(For draining and
protecting the freezing)
Do not place and lift
the acidic water draining
hose over higher than
the product.
×
○
×
○
×
Do not install
the product over
1 meter from a drain.
Keep the product out of
direct lays, a heater,
moisture and oil content.