Product Specifications

Summary of Operation Notices

36

37

Do not use this product for any purpose other than what’s described in this manual. 

Do not modify this product intentionally

Do not place heavy objects on this product.

Do not lift this product body holding the stainless steel tube, it will break. 

Always keep the disposal outlet open so water can drain.

Always use AC120V(American type) and  AC 220V~240V (European type) with this product.

KYK generation

Ⅱ: 

Always use 110V with this product.

Do not use overly contaminated water with this product. Tap water is best.

If there is a problem with this product, please call your service center.

Do not use hot water with this product. 

When the filter change signal is displayed, please change the filter as soon as possible.

When you do not use this product for more than two days, run water through it for 1~2 minutes before using.

When you use this product for the first time, run water through it for 2~3 minutes.

When you do not use this product for a long time (over 1 week), please unplug it, remove the filters, 

and dry it out.

Be careful when changing the filters to not damage the O ring. Change the filters carefully.  

Do not use well water, groundwater, contaminated water and water contained with high amounts of heavy metals.

Do not use water hotter than 35

C with this product. Room temperature water is best. 

Do not supply unit with ionized water.

Do not use alcohol for cleaning and washing the product. (Only use a gentle soap)

Change the filter regularly.

Do not take this product apart.

Do not shock or shake the unit.

Summary of Operation Notices

Manufacturer Approval Code

Product Name

Manufacturing Company

Manufacturing No. and Date

Composition and Water Supply Typ

Available Temperature

Electrolysis Method

LCD Display

Size and weight

Standard Voltage and Frequency

The object of Product

Electrical Consumption

Mineral Port

Power Source Protector

Over-current Detector

Over Temperature Protector

Electr-

olysis

Filter

OutputCapacity

Electrolysis Ability

Electrolysis Cell

Electrode Sheet Wash

Filter Life Estimate

Message to indicate

Filter Change

Filtering Material 
(Made in Korea)

Filter change
instructions

This product is connected directly to tap water and 

creates alkaline reduced water by first purifying 

the water with two special hybrid filters, then ionizing 

the water using 5 or 7 platinized titanium plates.

5

C ~ 30

C                                                                                           Touch sensor

Continuous electrolysis (including flow sensor)                                  1.5~ 3.0kgf/cm

2

Displays pH and ORP levels, 7 colors, water flow rate per minute, water purification, 

sound indicator, filter life for 1

st

and 2

nd

filter, auto-diagnosis codes, water purification

2 liter of alkali water/minute, 1.5 liters acidic water/minute

4 levels of acidic water, filtered only water

5 or 7 sheets of Platinized Titanium     KYK generation

Ⅱ: 

7 sheets of Platinized Titanium

Automatic washing (controlled by mycom)

1st filter: 6,000 liters      2nd filter: 9,000 liters 

(may differ region to region, nation to nation)

KYK generation

Ⅱ: 

1st filter: 6,000 liters       2nd filter: 6,000 liters

Displays on LCD display when the filter life indicator reaches 70 liters. 

If the taste and smell of water is not normal, you should change the filter anyway.

1

st

filter: 

composite filter

2

nd

filter:

composite filter

Filter Change (see the user manual)

Adding Calcium for Forced Dissolution

Fuse 250V AC,5A

Automatically stops the output of electrolytic cells

Temperature detector circuit installed inside SMPS power supply automatically stops the device. 

2213   

Alkaline Water Ionizer

KYK Co., Ltd. 

(#406,407 Sangdaewon-Dong Joongwon-Gu, Sungnam City, Kyunggi-Do, Korea)

See Backside of Product

80W (while operating)

07-667  

KYK generation

Ⅱ,

KYK25000, KYK30000, KYK33000

Product Approval Code

Model

Available Water

Pressure

Controlling Method

Standing or wall-mounted. Direct connection to tap water. 

Size: 340(W) x 340 (H) x 150 (D) (mm),      Weight:6kg

AC120V, 60Hz(American type) and  AC 220V~240V, 50/60Hz (European type)

Production of alkali water over pH 8.5 for drinking

KYK generation

Ⅱ: 

AC 110V,  50/60Hz 

KYK generation

Ⅱ: 

300W (while operating)

Содержание KYK Generation II

Страница 1: ...440 Sangdaewon Dong Joongwon Gu Sungnam City Kyunggi Do KOREA zipcode 462 120 82 31 777 3939 FAX 82 31 777 3456 COMMON USE MANUAL KYK Co Ltd promises to treat every customer fairly and respectfully w...

Страница 2: ...convenience and an improvement of product you will contact us at any time Again we sincerely value you as our customer and hope that this will be the beginning of a satisfying relationship Thank you S...

Страница 3: ...al due to the wide range of tap water quality in North America Non programmable ionizers cannot adjust to local tap water conditions so these ionizers are at the mercy of your tap water and a handful...

Страница 4: ...ents Stainless Steel Water Output Hose Output for alkaline acidic or purified water as selected by user LCD Display Displays pH ORP remaining filter life both filters error messages and water flow rat...

Страница 5: ...on in Liters Minute Voice Voice prompt on off Voice level pH Level pH level display toggled between pH using SET Touch Sensor Filter 1 Filter life remaining for 1st filter in liters Filter 2 Filter li...

Страница 6: ...ch sensor to increase or decrease the pH level alkalinity of water to be produced The pH level or the ORP value of the water being produced will be displayed on the LCD display Touch the Set touch sen...

Страница 7: ...6 setting the pH level of the incoming water step 8 and maximizing the ORP value step 14 You may also consider performing step 12 You must start at step 1 You can exit programming at any time by touch...

Страница 8: ...tioxidant capabilities more ability to counter free radical activity in the body It is recommended that you do this Hold the touch sensor down to obtain the highest negative ORP value and then touch t...

Страница 9: ...order it separately We accept a request in the A S center Warning You wrap the tape for preventing the leakage 4 5 times not to harm on the connection between nipple and piping and after complete con...

Страница 10: ...inlet in 11 page You have to cut the acidic water draining hose within 1m because if the length is over 1 m we will be possible to smell in the water The acidic water draining hose is placed lower th...

Страница 11: ...tallation Troubleshooting 1 If there is no water flow Check to make sure you removed the rubber stoppers on the inlet and outlet valves Check the faucet or under sink adapter to make sure that the val...

Страница 12: ...ced in the sink The product power cord is plugged into an above the counter electrical outlet Ionized water is delivered via the ionized water output hose on top of the product The information on page...

Страница 13: ...ure the tubing is pressed all the way into the connector IMPORTANT Note To remove tubing from a quick connect connector push the ring on the connector in towards the body of the product and gently pul...

Страница 14: ...27 Plug the Genesis power cord into a AC120V American type and AC 220V 240V European type electrical outlet 28 Adjust the input water pressure water flow rate into the product using the faucet You wan...

Страница 15: ...e steel flex hose onto the male threads of the diverter valve Tighten securely Feed the 1 4 tubing connected to the IN quick connect connector on the bottom of the product down through the access hole...

Страница 16: ...s First rinse rick in pH 8 5 alkaline water and then cook that rice in pH 10 0 water to quicken cooking time reduce damage to the rice and maintain it natural flavor Remove spots and stains Reduce det...

Страница 17: ...nt part 4 Hold the filter and turn it to the right OPEN then pull out The old filter can now be taken out of the product 5 Please remove the safety seal of the new filter Insert the new filter bottom...

Страница 18: ...t off drinking the 1ss alkaline water level 8 5 pH and drink 2 3 glasses a day for 1 week then drink 2 3 glasses a day of the 2nd level alkaline water 9 0 pH for the second week Typically most adults...

Страница 19: ...etector Over Temperature Protector Electr olysis Filter OutputCapacity Electrolysis Ability Electrolysis Cell Electrode Sheet Wash Filter Life Estimate Message to indicate Filter Change Filtering Mate...

Страница 20: ...age 5 Damage is caused by using an imitation filter 6 Damage is caused by a natural disaster 7 Damage is caused by exposing the electronics to water or moisture Terms of Warranty one years parts and l...

Отзывы: