Another Installation Options

Installation

Components

Faucet Diverter Valve 

see faucet diverter valve components – Page 27

Water Supply Tubing (to product) 

see genesis bottom view – page 27

Water Disposal Tubing (from product)

see product bottom view – page 27

Ionized Water STAINLESS Steel Delivery Hose 

See productFront View – page 28

Product Power Cord

- see page 28

Product Touch Sensor Panel

– See page 28 

LCD DISPLAY

– See page 28

Acid water drain tubing/suction cup holder

See acid water drain tubing – page 28

~

Countertop Installation Components

There are two installation configurations.

Connection to the faucet. 

With this installation configuration option, the product sits on the countertop and the water

supply line is connected to your faucet by removing the existing aerator and installing the

provided faucet diverter valve. The drain line from the product is placed in the sink. 

The product power cord is plugged into an above the counter electrical outlet. 

Ionized water is delivered via the ionized water output hose on top of the product.

The  information  on  pages  25  &  26  provides  installation  instructions  for  the  product

countertop installation option. This is the simplest installation configuration.

Connection to the cold water line.

Your product is shipped with an optional cold water supply line diverter valve. 

This diverter valve is installed on the cold water supply line in the cupboard area below the

sink. This eliminates the need to attach the product water supply to the faucet head. 

To implement this option, you will need a 1/4" access hole through either the lip of the sink

or the counter top depending on what type of sink you have and how it is mounted. 

If  you  have  an  accessory  you  do  not  use  (like  a  soap  dispenser)  you  can  remove  that

accessory and use that hole.

If an access hole is not available, you will need to drill one.

Instructions for installing the cold water supply line diverter valve are on page 26.

Содержание KYK Generation II

Страница 1: ...440 Sangdaewon Dong Joongwon Gu Sungnam City Kyunggi Do KOREA zipcode 462 120 82 31 777 3939 FAX 82 31 777 3456 COMMON USE MANUAL KYK Co Ltd promises to treat every customer fairly and respectfully w...

Страница 2: ...convenience and an improvement of product you will contact us at any time Again we sincerely value you as our customer and hope that this will be the beginning of a satisfying relationship Thank you S...

Страница 3: ...al due to the wide range of tap water quality in North America Non programmable ionizers cannot adjust to local tap water conditions so these ionizers are at the mercy of your tap water and a handful...

Страница 4: ...ents Stainless Steel Water Output Hose Output for alkaline acidic or purified water as selected by user LCD Display Displays pH ORP remaining filter life both filters error messages and water flow rat...

Страница 5: ...on in Liters Minute Voice Voice prompt on off Voice level pH Level pH level display toggled between pH using SET Touch Sensor Filter 1 Filter life remaining for 1st filter in liters Filter 2 Filter li...

Страница 6: ...ch sensor to increase or decrease the pH level alkalinity of water to be produced The pH level or the ORP value of the water being produced will be displayed on the LCD display Touch the Set touch sen...

Страница 7: ...6 setting the pH level of the incoming water step 8 and maximizing the ORP value step 14 You may also consider performing step 12 You must start at step 1 You can exit programming at any time by touch...

Страница 8: ...tioxidant capabilities more ability to counter free radical activity in the body It is recommended that you do this Hold the touch sensor down to obtain the highest negative ORP value and then touch t...

Страница 9: ...order it separately We accept a request in the A S center Warning You wrap the tape for preventing the leakage 4 5 times not to harm on the connection between nipple and piping and after complete con...

Страница 10: ...inlet in 11 page You have to cut the acidic water draining hose within 1m because if the length is over 1 m we will be possible to smell in the water The acidic water draining hose is placed lower th...

Страница 11: ...tallation Troubleshooting 1 If there is no water flow Check to make sure you removed the rubber stoppers on the inlet and outlet valves Check the faucet or under sink adapter to make sure that the val...

Страница 12: ...ced in the sink The product power cord is plugged into an above the counter electrical outlet Ionized water is delivered via the ionized water output hose on top of the product The information on page...

Страница 13: ...ure the tubing is pressed all the way into the connector IMPORTANT Note To remove tubing from a quick connect connector push the ring on the connector in towards the body of the product and gently pul...

Страница 14: ...27 Plug the Genesis power cord into a AC120V American type and AC 220V 240V European type electrical outlet 28 Adjust the input water pressure water flow rate into the product using the faucet You wan...

Страница 15: ...e steel flex hose onto the male threads of the diverter valve Tighten securely Feed the 1 4 tubing connected to the IN quick connect connector on the bottom of the product down through the access hole...

Страница 16: ...s First rinse rick in pH 8 5 alkaline water and then cook that rice in pH 10 0 water to quicken cooking time reduce damage to the rice and maintain it natural flavor Remove spots and stains Reduce det...

Страница 17: ...nt part 4 Hold the filter and turn it to the right OPEN then pull out The old filter can now be taken out of the product 5 Please remove the safety seal of the new filter Insert the new filter bottom...

Страница 18: ...t off drinking the 1ss alkaline water level 8 5 pH and drink 2 3 glasses a day for 1 week then drink 2 3 glasses a day of the 2nd level alkaline water 9 0 pH for the second week Typically most adults...

Страница 19: ...etector Over Temperature Protector Electr olysis Filter OutputCapacity Electrolysis Ability Electrolysis Cell Electrode Sheet Wash Filter Life Estimate Message to indicate Filter Change Filtering Mate...

Страница 20: ...age 5 Damage is caused by using an imitation filter 6 Damage is caused by a natural disaster 7 Damage is caused by exposing the electronics to water or moisture Terms of Warranty one years parts and l...

Отзывы: