background image

25

24

1

.

Lay the product on its back on your countertop where it will be placed when you are operating it so that

the bottom of the unit is accessible. 

2

.

Attach the power cord to the bottom of the product and turn the master power switch to the ON position.

See “Power Cord” on page 24. DO NOT plug the unit in at this time.

3

.

Press the power cord into the middle guide slot on the side from which the power cord will exit the unit

towards the electrical outlet into which the product will be plugged. 

4

.

Using a pair of scissors carefully cut the plastic clasps that are attached to the 1/4 inch tubing provided

with your product.

5

.

Cut this tubing into two equal halves.

6

.

Remove the gray plugs in the IN and OUT quick connect connector by locating the outer ring around the

plug, then pushing this ring toward the body of the product, while gently pulling the plug out.

7

.

Insert  one  end  of  one  of  the  tubing  halves  into  the  IN  quick  connect  connector  on  the  bottom  of  the

product.  See  “Bottom  View  (A)”  on  page  24.  To  insert  the  tubing,  hold  the  connector  with  one  hand  and

insert  the  tubing  into  the  connector  with  the  other  hand  until  it  is  pressed  all  the  way  into  the  connector

(IMPORTANT). 

8

.

Insert one end of the other tubing half into the OUT quick connect connector on the bottom of the Genesis.

See  “Bottom  View  (B)”  on  page  24.  Make  sure  the  tubing  is  pressed  all  the  way  into  the  connector

(IMPORTANT).

Note: To remove tubing from a quick connect connector, push the ring on the connector in (towards the body

of the product) and gently pull out the tubing, just like removing the plugs. 

9

.

Turn the connectors (and tubing) in the direction needed to exit the tubing toward the sink.

10

.

Press the tubing into the guides at the edge of the product. See “ Bottom View (E) on page 24.

11

.

Attach the tubing connected to the OUT connector to the acid line sink attachment. “See Acid Water

Drain Tubing” on page 24. This will insure that the IN tubing and the OUT tubing can be correctly identified

later without having to recheck the bottom of the unit.

12

.

Set the product in an upright position and place it where you intend to use it. 

13

.

Both the “IN” tubing and the “OUT” tubing should be exiting the product toward sink.

If they are not, lay the unit on its back and switch the direction of the connectors and tubing accordingly.

14

.

Locate  the  stainless  steel  faucet  head  diverter  valve  and  the  stainless  steel  male/male  adapter  and  set

these next to your sink.

A

Water Drain Tubing

B

Suction Cup

Delivery Hose Connection

Ionized Water Delivery Hose

A

1/4

Water Supply Tubing

B

Faucet Diverter Valve

C

:

Water Conter Knob

A

Water Supply Inlet Valve (Labeled in)

B

Drain Water Outlet Valve (Markee out)

C

:

Master power ON/OFF switch 

D

Power cord receptacle

E

:

Guides for Tubing and Power Cord

Power Cord

Touch Sensor Panel

Installation Components Continued

Countertop Installation Instructions

Содержание KYK Generation II

Страница 1: ...440 Sangdaewon Dong Joongwon Gu Sungnam City Kyunggi Do KOREA zipcode 462 120 82 31 777 3939 FAX 82 31 777 3456 COMMON USE MANUAL KYK Co Ltd promises to treat every customer fairly and respectfully w...

Страница 2: ...convenience and an improvement of product you will contact us at any time Again we sincerely value you as our customer and hope that this will be the beginning of a satisfying relationship Thank you S...

Страница 3: ...al due to the wide range of tap water quality in North America Non programmable ionizers cannot adjust to local tap water conditions so these ionizers are at the mercy of your tap water and a handful...

Страница 4: ...ents Stainless Steel Water Output Hose Output for alkaline acidic or purified water as selected by user LCD Display Displays pH ORP remaining filter life both filters error messages and water flow rat...

Страница 5: ...on in Liters Minute Voice Voice prompt on off Voice level pH Level pH level display toggled between pH using SET Touch Sensor Filter 1 Filter life remaining for 1st filter in liters Filter 2 Filter li...

Страница 6: ...ch sensor to increase or decrease the pH level alkalinity of water to be produced The pH level or the ORP value of the water being produced will be displayed on the LCD display Touch the Set touch sen...

Страница 7: ...6 setting the pH level of the incoming water step 8 and maximizing the ORP value step 14 You may also consider performing step 12 You must start at step 1 You can exit programming at any time by touch...

Страница 8: ...tioxidant capabilities more ability to counter free radical activity in the body It is recommended that you do this Hold the touch sensor down to obtain the highest negative ORP value and then touch t...

Страница 9: ...order it separately We accept a request in the A S center Warning You wrap the tape for preventing the leakage 4 5 times not to harm on the connection between nipple and piping and after complete con...

Страница 10: ...inlet in 11 page You have to cut the acidic water draining hose within 1m because if the length is over 1 m we will be possible to smell in the water The acidic water draining hose is placed lower th...

Страница 11: ...tallation Troubleshooting 1 If there is no water flow Check to make sure you removed the rubber stoppers on the inlet and outlet valves Check the faucet or under sink adapter to make sure that the val...

Страница 12: ...ced in the sink The product power cord is plugged into an above the counter electrical outlet Ionized water is delivered via the ionized water output hose on top of the product The information on page...

Страница 13: ...ure the tubing is pressed all the way into the connector IMPORTANT Note To remove tubing from a quick connect connector push the ring on the connector in towards the body of the product and gently pul...

Страница 14: ...27 Plug the Genesis power cord into a AC120V American type and AC 220V 240V European type electrical outlet 28 Adjust the input water pressure water flow rate into the product using the faucet You wan...

Страница 15: ...e steel flex hose onto the male threads of the diverter valve Tighten securely Feed the 1 4 tubing connected to the IN quick connect connector on the bottom of the product down through the access hole...

Страница 16: ...s First rinse rick in pH 8 5 alkaline water and then cook that rice in pH 10 0 water to quicken cooking time reduce damage to the rice and maintain it natural flavor Remove spots and stains Reduce det...

Страница 17: ...nt part 4 Hold the filter and turn it to the right OPEN then pull out The old filter can now be taken out of the product 5 Please remove the safety seal of the new filter Insert the new filter bottom...

Страница 18: ...t off drinking the 1ss alkaline water level 8 5 pH and drink 2 3 glasses a day for 1 week then drink 2 3 glasses a day of the 2nd level alkaline water 9 0 pH for the second week Typically most adults...

Страница 19: ...etector Over Temperature Protector Electr olysis Filter OutputCapacity Electrolysis Ability Electrolysis Cell Electrode Sheet Wash Filter Life Estimate Message to indicate Filter Change Filtering Mate...

Страница 20: ...age 5 Damage is caused by using an imitation filter 6 Damage is caused by a natural disaster 7 Damage is caused by exposing the electronics to water or moisture Terms of Warranty one years parts and l...

Отзывы: