After locking all raw water of installation area. (Ii is mainly placed at a tap water meter)
❷
Separate from the pipe for cold and hot water connected with a tap. (See the figure in 13 page)
※
Warning-When you decompose the product, if a rubber packing attached on the nipple for
preventing the leakage is worn out, you will change that. Unless it will be cause a leakage
of product.
❸
You link the switch valve with the nipple with a hole connected in
❷
as shown in the figure.
※
You wrap the tape for preventing the leakage proper times not to harm on the connection
between nipple and piping and after complete connection, you have to adjust the direction
of a valve not to make a problem on the connection with the product.
(As shown in the figure, after stopping down the nipple, the switch valve will be horizontal
so you control the amount of leakage tape as the same amount.)
❹
The check items for controlling the water pressure
The proper water pressure for the normal operation is 1.5~3.0kgf/cm2.
Keep the product out of the direct rays of the sun and do not change the original setting
values intentionally.
How to install - Under sink water supply system/General model type
How to install and the check list
Information-Connecting with a tap type
Fixing with a screw type- Insert at the end of a tap by
adjusting a balance and stop out a screw.
Formal ring-Remove the ring from the end of a tap
and turn and insert a formal ring.
After linking the ON/OFF valve with a tap and connect with
the inlet of the product.
A hose band
Connecting with the product
Check list
Installation Troubleshooting
1⃞
If there is no water flow:
☞
Check to make sure you removed the rubber stoppers on the inlet and outlet valves.
☞
Check the faucet or under sink adapter to make sure that the valve is open and water
can get through.
2⃞
If there is an improper ratio of alkaline water and acidic water:
☞
Increase the water pressure to at least 1.5 liters a minute.
If the water pressure is too low, then there will be too much acidic water and
not enough alkaline.
☞
Check to make sure the draining hose isn’t bent or kinked.
If it is, there won’t be enough acid water and the alkaline water will be weak.
3⃞
After finishing installation and troubleshooting, connect the KYK Product to
an AC 110V or 220V outlet.
All hookup part of pipe arrangement has to be covered by teflon tape for avoiding the leakage and you
control the bounding number of tape for keeping the level of a horizontality and a perpendicularity.
When you decompose and reassemble the product, if you give the over force, it will be possible to leak after
assembling the product because of a pipe arrangement distortion of raw water, a break out of rubber packing
and a breakage.
※
How to link the hose with the product after connecting a tap water pipe
- Do as the same way described in 17 and 18 page.
※Reference
▶
The case that ground water or solid quality of water is used.
-If the quality of groundwater is bad, you must mount a preprocessing filter.
-For the life and performance of the product, push the acidic water button 1~2
times in one week and drain acidic water during 1~2 minutes.
-In the area which has high solidity and calcareous, there is soiled as white by the calcium,
so in the middle of water flow, you push the acidic water button 2~3 times in the week and