SECTION VI
Maintenance
P 6.7
5.
Install the new sensor.
6.
Adjust the sensor position so there is a 0.032”
(0.8mm) gap between the sensor tip and the
end of the pick pivot pin as the pin is moved
toward the sensor face. Tighten the sensor in
place in the mounting bracket.
7.
Connect the electrical cable to the sensor.
8.
The sensor mounting bracket should be flush to
1/16” (1.6mm) below the bottom of the upper
stepper mount. The vertical position of the pick
sensor affects the closure height in relation to
the closing belts. The proper position will place
the closure opening at the top of the outside
drive belt (Figure 6.16).
9.
Install the shield and covers.
10. Cycle the closer to verify the lok is in the proper
location.
893 09 12
Figure 6.17
Indicator light ”On”
(Breakoff sensor)
Figure 6.15
0.032 (0.8mm)
Pick sensor
Pick pivot pin
Closure opening to be even with the top of the lower
drive belt (as indicated by white arrow).
Figure 6.16
Содержание 893A ULTRA
Страница 10: ...This page intentionally blank ...
Страница 16: ...This page intentionally blank ...
Страница 26: ...This page intentionally blank ...
Страница 56: ......
Страница 60: ...This page intentionally blank ...
Страница 80: ...ELECTRICAL COMPONENTS Figure 8 11 893 05 15 SECTION VIII Parts Identification P 8 20 ...
Страница 82: ...COVERS AND GUARDS Figure 8 12 P 8 22 SECTION VIII Parts Identification 893 05 15 ...
Страница 88: ...P 8 28 SECTION VIII Parts Identification 893 05 15 PARTS LIST KIT Z8093003 MAST UPRIGHT NO PRINTER Figure 8 15 ...
Страница 97: ...This page intentionally blank ...
Страница 100: ...This page intentionally blank ...