- 14 -
(1) Press
+
+
at same time in 5 second, display flashes ,
(2) Press
or to choose the parameter you want to adjust
(3)
Press
again to enter into interface
(4)
Press
or
to adjust the value setting.
(5)
Finally press
once again to save the data or press
to save and
quick-exit the parameter setting .
Para
met
er
Meaning
Range
Default
Remarks
0
To set the entering water
temp. under cooling mode
7-35°C
28°C
Not
adjustable
1
To set the entering water
temp. under heating mode
15-42°C
28°C
Adjustable
2
Entry into defrosting time
period
30-90MIN
40MIN
Adjustable
3
Terms of Entry defrosting
function
-30°C to0°C
-7°C
Adjustable
4
Terms of Exit defrosting
2 to 30°C
20°C
Adjustable
5
Time of Exit defrosting
1 to 12MIN
12MIN
Adjustable
6
Mode: 0 Heat 1 Heat and
Cool
0-1
0
Not
adjustable
7
Mode selection of
Electronic expansion valve
0-1
1(auto)
Adjustable
A
Manual adjustment steps
of electronic expansion
valve
18-94
70
Adjustable
Содержание Green Energy ECO 10
Страница 2: ......
Страница 22: ...20 8 Electrical Wiring ECO 3 5 8 10 wiring diagram...
Страница 23: ...21 ECO 12 wiring diagram...
Страница 24: ...22 9 Figures of the pump 9 1 Exploded Diagram...
Страница 26: ...24 10 Accessories Anti vibration base 4 pcs Beneath the machine stand Draining jet 2 pcs Under the bottom panel...
Страница 27: ...25 11 Warranty and Returns 11 1 Warranty...
Страница 49: ...47 8 Verkabelung ECO 3 5 8 10...
Страница 50: ...48 ECO 12...
Страница 51: ...49 9 Fakten zur Pumpe 9 1 Explodierte Zeichnung...
Страница 57: ......
Страница 58: ...A0111KWDE01...